| Product Characteristics |
| Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
| Process Connection | Threaded connection R 1/2 DN15 |
| Media | Compressed air |
| Medium Temperature [° C] | -10 - 60 |
| Min. bursting pressure [bar] | 64 |
| Min. bursting pressure [MPa] | 6.4 |
| Pressure Rating [bar] | 16 |
| Pressure Rating [MPa] | 1.6 |
| MAWP (for Applications According to CRN) [bar] | 16 |
| Electrical Data |
| Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
| Current Consumption [mA] | < 80 |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | 1 |
| Inputs / Outputs |
| Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
| Inputs |
| Inputs | Counter reset |
| Outputs |
| Output Signal | Switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Electrical Design | PNP/NPN |
| Number of Digital Outputs | 2 |
| Output Function | Normally open / closed; (configurable) |
| Maximum Voltage Drop Switching Output DC [V] | 2.5 |
| Permanent Current Rating of Switching Output DC [mA] | 150; (per output) |
| Number of Analog Outputs | 1 |
| Analog Current Output [mA] | 4 - 20; (scalable) |
| Maximum Load [Ω ] | 500 |
| Pulse output | Consumed quantity meter |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Yes (non-latching) |
| Overload Protection | Yes |
| Measuring/Setting Range |
| Volumetric flow quantity monitoring |
| Pulse length [s] | 0.002 - 2 |
| Accuracy / Deviations |
| Temperature Coefficient [1/K] | ± 0,07 % MW |
| Accuracy (in the Measuring Range) | ± (15 % MW + 1,5 % MEW); (maximum value to be achieved for air quality class 344 (DIN8573-1: 2010); when using pipes of tolerance class T3/T4; inlet and outlet pipe lengths without edges and abrupt diameter changes; inner surface of the pipe free of burrs) |
| Repeatability | ± 1,5 % MW |
| Temperature Monitoring |
| Accuracy [K] | ± 0,5; (medium flow in the limit area of the flow measurement range) |
| Reaction Times |
| Response Time [s] | 0.1; (dAP = 0) |
| Damping Process Value dAP [s] | 0 - 5 |
| Temperature Monitoring |
| Dynamic Response T05 / T09 [s] | T09 = 0,5 |
| Software / Programming |
| Parameter Setting | Hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display Unit; totalizer |
| Interfaces |
| Communication Interface | IO-Link |
| Transmission Type | COM2 (38,4 kBaud) |
| IO-Link Revision | 1.1 |
| SDCI Standard | IEC 61131-9 CDV |
| Profiles | Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) |
| SIO Mode | Yes |
| Required Master Port Class | A |
| Process Data Analog | 6 |
| Process Data Binary | 2 |
| Minimum Process Cycle Time [ms] | 5.9 |
| Operating Conditions |
| Ambient Temperature [° C] | 0 - 60 |
| Storage Temperature [° C] | -20 - 85 |
| Maximum Relative Air Humidity [%] | 90 |
| Protection | |
| MTTF [Years] | 195 |
| Pressure Equipment Directive | Sound engineering practice; can be used for stable gases fluid group 2 |
| Mechanical Data |
| Weight [g] | 546.5 |
| Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM |
| Materials (Wetted Parts) | Stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; acrylate |
| Process Connection | Threaded connection R 1/2 DN15 |
| Electrical Connection |
| Connection | Connector: 1 x M12; coding: A |