Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Fluke
Three-Phase Energy Analyzer with Current Probes

Fluke FLUKE-434-II Three-Phase Energy Analyzer with Current Probes

Brand: Fluke
Part #:
FLUKE-434-II
Condition:
Brand New
Contact Us For Pricing
Check availability
Contact Us For Pricing
Manufacturer warranty

Description

Contact Us For Pricing
Check availability

Technical details

Main features
  • Accuracy ±5%
  • Measurement Range 1 to 10
  • Included Current Probes
  • Type Energy
  • Resolution 0.01
  • Operating Temperature 32 to 104°F (0 to 40°C) 32 to 122°F (0 to 50°C) excluding battery
  • Storage Temperature -4 to 140°F (-20 to 60°C)
  • Interfaces Mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
  • Phase angle Measurement Range: -360 to 0° Resolution: 1° Accuracy: ±n x 1°
  • Humidity 95% RH non-condensing at 50 to 86°F (10 to 30°C) 75% RH non-condensing at 86 to 104°F (30 to 40°C) 45% RH non-condensing at 104 to 122°F (40 to 50°C)
  • Maximum Operating Altitude Up to 6666' (2000 m) for CAT IV 600 V, CAT III 1000 V Up to 10,000' (3000 m) for CAT III 600 V, CAT II 1000 V Maximum storage altitude 40,000' (12 km)
  • Vrms (AC + DC) Measurement Range: 1 to 1000 V phase to neutral Resolution: 0.1 V Accuracy: ±0.1% of nominal voltage
  • Vpk Measurement range: 1 to 1400 Vpk Resolution: 1 V Accuracy: 5% of nominal voltage
  • Voltage Crest Factor (CF) Measurement Range: 1.0 > 2.8 Resolution: 0.01 Accuracy: ±5%
  • Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
  • Vrms1/2 Measurement Range: 1 to 1000 V phase to neutral Resolution: 0.1 V Accuracy: ±1% of nominal voltage
  • Vfund Measurement Range: 1 to 1000 V phase to neutral Resolution: 0.1 V Accuracy: ±0.5% of nominal voltage
  • i430-Flex 1x Measurement Range: 5 to 6000 A Resolution: 1 A Accuracy: ±0.5% ±5 counts, Measurement Range: 5 to 6000 A Resolution: 1 A Accuracy: ±1% ±10 counts
  • i430-Flex 10x Measurement Range: 0.5 to 600 A Resolution: 0.1 A Accuracy: ±0.5% ±5 counts, Measurement Range: 0.5 to 600 A Resolution: 0.1 A Accuracy: ±1% ±10 counts
  • 1mV/A 1x Measurement Range: 5 to 2000 A Resolution: 1 A Accuracy: ±0.5% ±5 counts, Measurement Range: 5 to 2000 A Resolution: 1 A Accuracy: ±1% ±10 counts
  • 1mV/A 10x Measurement Range: 0.5 to 200 A (AC only) Resolution: 0.1 A Accuracy: ±0.5% ±5 counts, Measurement Range: 0.5 to 200 A (AC only) Resolution: 0.1 A Accuracy: ±1% ±10 counts
  • i430-Flex Measurement Range: 8400 Apk Resolution: 1 Arms Accuracy: ±5%, Measurement Range: Max 6000 MW Resolution: 0.1 W to 1 MW Accuracy: ±1% ±10 counts
  • 1mV/A Measurement Range: 5500 Apk Resolution: 1 Arms Accuracy: ±5%
  • Fluke 434 at 50 Hz Nominal Measurement Range: 42.50 to 57.50 Hz Resolution: 0.01 Hz Accuracy: ±0.01 Hz
  • Fluke 434 at 60 Hz Nominal Measurement Range: 51.00 to 69.00 Hz Resolution: 0.01 Hz Accuracy: ±0.01 Hz
  • 1 mV/A Measurement Range: Max 2000 MW Resolution: 0.1 W to 1 MW Accuracy: ±1% ±10 counts
  • Power Factor (Cos j/DPF) Measurement Range: 0 to 1 Resolution: 0.001 Accuracy: ±0.1% at nominal load conditions
  • Harmonic Order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
  • Inter-Harmonic Order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
  • Volts % (f) Measurement Range: 0.0 to 100% Resolution: 0.1% Accuracy: ±0.1% ±n x 0.1%
  • Volts % (r) Measurement Range: 0.0 to 100% Resolution: 0.1% Accuracy: ±0.1% ±n x 0.4%
  • Volts % (Absolute) Measurement Range: 0.0 to 1000 V Resolution: 0.1 V Accuracy: ±5%
  • Volts % (THD) Measurement Range: 0.0 to 100% Resolution: 0.1% Accuracy: ±2.5%
  • Amps % (f) Measurement Range: 0.0 to 100% Resolution: 0.1% Accuracy: ±0.1% ±n x 0.1%
  • Amps % (r) Measurement Range: 0.0 to 100% Resolution: 0.1% Accuracy: ±0.1% ±n x 0.4%
  • Amps % (Absolute) Measurement Range: 0.0 to 600 A Resolution: 0.1 A Accuracy: ±5% ±5 counts
  • Amps % (THD) Measurement Range: 0.0 to 100% Resolution: 0.1% Accuracy: ±2.5%
  • Watts % (f or r) Measurement Range: 0.0 to 100% Resolution: 0.1% Accuracy: ±n x 2%
  • Watts % (Absolute) Measurement Range: Depends on clamp scaling and V nominal Accuracy: ±5% ±n x 2% ±10 counts
  • Watts % (THD) Measurement Range: 0.0 to 100% Resolution: 0.1% Accuracy: ±5%
  • Plt, Pst, Pst (1 min) Pinst Measurement Range: 0.00 to 20.00 Resolution: 0.01 Accuracy: ±5%
  • Volts % Measurement Range: 0.0 to 20.0% Resolution: 0.1% Accuracy: ±0.1%
  • Amps % Measurement Range: 0.0 to 20.0% Resolution: 0.1% Accuracy: ±1%
  • Threshold Levels Threshold, limits and signaling duration is programable for two signaling frequencies
  • Signaling Frequency Measurement Range: 60 to 3000 Hz Resolution: 0.1 Hz
  • Relative V % Measurement Range: 0 to 100% Resolution: 0.1% Accuracy: ±0.4%
  • Absolute V3s (3 Second Average) Measurement Range: 0.0 to 1000 V Resolution: 0.1 V Accuracy: ±5% of nominal voltage