Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Fluke
Multifunction Tester with US Plug

Fluke FLK-1662 US Multifunction Tester with US Plug

Brand: Fluke
Part #:
FLK-1662 US
Condition:
Brand New

Choose Plug Type

$1,820.00 /Each
Free shipping
$1,820.00 /Each

Notification

This product will be drop-shipped directly from the manufacturer. We will provide you with the manufacturer's lead time once advised.

Manufacturer warranty

Description

$1,820.00 /Each
Free shipping

Technical details

Main features
  • Range 500 V, 10 Ω / 0.001 Ω / High current mΩ mode, 1000 A / 10 kA (50 kA)
  • Measurement Range RCD Type G: 310 ms, 50 ms RCD Type S: 510 ms, 160 ms
  • Resolution 0.1 V, 0.01 Ω / 0.1 Ω / 1 Ω, 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ, 1 A / 0.1 kA
  • Plug Type US plug
  • Overload Protection 660 V rms
  • Current Range 30% to 110% of RCD rated current¹
  • Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
  • Performance EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition
  • Step Size 10% of IΔN²
  • Sealing IP-40
  • Size (L x W x H) 10 x 25 x 12.5 cm
  • Test Voltage 100 V 250 V 500 V 1000 V
  • Input Impedance 360 kΩ
  • Overvoltage CAT III / 500V; CAT IV 300V
  • Notes Responds to AC General, no delay Time delay Responds to pulsed signal Responds to smooth DC signal, 1000 mA type AC only 700 mA maximum type A in VAR mode, 30% to 150% for Type A IΔN > 10 mA 30% to 210% for Type A IΔN = 10 mA 20% to 210% for Type B
  • Measurement Accuracy ±5%
  • Open Circuit Voltage >4 V
  • Accuracy 45 Hz – 66 Hz 0.8% + 3
  • Range (autoranging) 20 Ω / 200 Ω / 2000 Ω
  • Accuracy of tTest voltage (at rated test current) +10%, -0%
  • Insulation resistance range 20 MΩ / 50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ
  • Test current 1 mA at 50 kΩ 1 mA at 100 kΩ 1 mA at 250 kΩ 1 mA at 500 kΩ 1 mA at 1 MΩ
  • Computation Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
  • RCD Type A, AC, G, S
  • Current settings 10-30-100-300-500-1000 mA – VAR 10-30-100 mA
  • Multiplier x ½, x 1 x 5
  • Specified trip current ranges (EN 61008-1) 50% to 100% for Type AC 35% to 140% for Type A (>10 mA) 35% to 200% for Type A (≤10 mA) 50% to 200% for Type B ²5% for Type B
  • Weight (incl. batteries) 1.3 kg
  • Battery size, quantity Type AA, 6 ea.