Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Tek-Trol
NEMA 4X Modbus Scanner Indicator

Tek-Trol Tek-LCD 7804A-AX0 NEMA 4X Modbus Scanner Indicator

Part #:
Tek-LCD 7804A-AX0
Model #:
Tek-LCD 7804A Series
Condition:
Brand New
$1,567.00 /Each
$1,685.00 You save $118.00 7%
Free shipping
Typically In Stock
Check availability
$1,567.00 /Each
$1,685.00 You save $118.00 7%
Manufacturer warranty

Description

$1,567.00 /Each
$1,685.00 You save $118.00 7%
Free shipping
Typically In Stock
Check availability

Technical details

Main features
  • Weight 1.65 lbs (26.4 oz, .75 kg)
  • Mounting May be mounted directly to the conduit. Two slotted flanges for wall mounting or NPS 1-1/2" to 2-1/2" or DN 0.13 ft to 0.21 ft pipe mounting.
  • Input Power 9-30 VDC, 38 mA max. 2.2 W
  • Overall Dimensions 5.67″ x 5.25″ x 4.18″ (0.47 ft x 0.43 ft x 0.34 ft) (W x H x D)
  • Backlight White LED, 10-sec auto-off when battery-powered. Backlight deactivated below temperature ~ -20°C (-4°F)
  • Over Range Upper Display: Decimal display flashes 99999 The level display flashes to 399FT 1115/16 IN Lower Display: Flashes 9999999
  • Under Range Upper Display: Decimal display flashes -9999. The level display flashes to 399 FT, 11 and 15/16 IN Lower Display: Flashes -999999
  • Display Assignment Top and Bottom Display: Process Variables (PV); Alternating PV and Units, Tag and PV, or Tag, PV, and Units; Pulse Input Rate, Total, or Grand Total with Alternating Tag. Units and tags are independent for each PV, pulse input rate, total, and total. Note: On feet and inches display models, the top display is used only for level Modbus process variables or math channels.
  • Programming Method Four SafeTouch through-window buttons when the cover is installed. Four internal push buttons when the cover is removed.
  • Recalibration Calibrated at the factory to read frequency in Hz. No recalibration is required.
  • Display Orientation The display may be mounted at 90° increments up to 270° from default orientation.
  • Password Menu Three programmable password selections can be used for the following: restrict modification of settings, prevent resetting the total or grand total without the password, or permanently lock out the ability to change or reset the grand total or any grand total-related settings(making a non-resettable grand total). Pass: Restricts modifications of programmed settings to require re-entering the password to make changes. Pass T: Restricts the reset of the total to require re-entering the password. Disables the manual mode reset contact. Pass GT: Restricts the reset of grand total to require re-entering the password. May enable a non-resettable grand total and permanent lockout of grand total-related settings with a specific password.
  • Decimal Display Top Display: Five Digits (0 to 99999), 0.7″ (0.05 ft) high, 7-segment, automatic lead zero blanking. Bottom Display: Seven Characters, 0.4″ (0.03 ft) high, 14-segment, automatic lead zero blanking. Symbols: Total, grand total, high alarm, low alarm, SafeTouch button sleep mode/disable, password lock.
  • Feet & Inches Display Top Display: 0.60″ (0.05 ft) high, 0 to 399 FT, 11 and 15/16 IN, 7-segment, programmable 1/16 or 1/8 fraction display. Bottom Display: Seven Characters, 0.4″ (0.03 ft) high, 14-segment, 7-digits. Tank Level Indicator: 20-segments, F (Full) and E (Empty). Alarm Indication: High and low alarm Backlight: White
  • Alarm Indication Flashing display plus HI/LO (alarm) or SET indicators.
  • Scan and Update Rate Ambient > -20°C (-4°F): Modbus PV scan rate programmable from 2 to 99 seconds per PV. Tag and units programmable for 1 to 5-second alternation. Pulse input variables update 1/second. Rate update is dependent on gate settings. Ambient < -20°C (-4°F): All Modbus scan, alternating units and tags, and pulse input variables update/10 seconds minimum.

Related items.

Customers buy together with this.

Reviews.

There are currently no reviews for this product. You can leave the first review and share your experience.