Input |
Nominal Input Voltage and Frequency | 120 VAC, 50 / 60 Hz (Default) ; 230 VAC, 50 / 60Hz (Internal jumper setting) |
AC Input Current | - at 120 VAC: 15.9A,
- at 230 VAC: 8.6A
|
AC Input Connection | - Attached Power Cord: 6 ft length
- 3 x AWG#12 wire size
- NEMA5-20P Plug
|
Output |
Charging Current | 80A (Full Power Bulk Stage Current) ; 40A (Half Power Bulk Stage Current) |
Charging Stages | - 3 Stages (DIP Switch setting - Default): Bulk, Absorption and Float
- 2 Stages (DIP Switch setting): Bulk and Float
|
Charging Voltages | - Absorption: 14.4 VDC (Default)
- 14.0 VDC (DIP Switch setting)
- Disable (DIP Switch setting)
- Float: 13.5 VD
|
NO. of Charging Banks | 2 |
Output Connections | - Tubular Hole with Set Screw
- Hole Diameter: 7.9 mm
- 5/16 in
- Set Screw Size 5/16” x 24 TPI
|
Monitoring |
LED Display | Green LED: Half Power Mode is selected |
Analogue Meter | Ammeter: 0 to 50A; Voltmeter: 0-15 VDC |
Cooling |
Temperature / Load Controlled Fan | - Switch on when Charging current rises to 15A ± 1A
- Switch off when Charging current drops to 8A ± 0.5A
- Switch on when Power Transformer Temperature rises to 105 ± 5°C/ 221 ± 9°F
|
Protections |
Output Short Circuit | No Output Voltage. Manual reset |
Input Overload | 20A Input side fuse will bLow (120 VAC Input) |
Output Overload | Electronic current limit at 50A (Full Power Mode) / 25±1A (Half Power Mode) |
Reverse Polarity ON Output SID | 3 x 30A Output side fuses will bLow |
Over Temperature Shutdown | Power Transformer Temperature rises to 105°C ±5°C / 221°F ±9°F. Manual reset |
Fuses |
Internal AC Input Side Fuse (120 VAC Operation) | - 20A, 250V;
- Size 6.3mm x 32mm
- Time Delay Type
- Mfr.: Littelfuse 0218012 or equivalent
|
Internal AC Input Side Fuse (230 VAC Operation) | 20A, 250V; Size 6.3mm x 32mm; Time Delay Type Mfr.: Littelfuse 0325020 or equivalent |
Internal DC Output Side Fuse | - 90A [3 x (32V, 30A) in parallel]
- Automotive Blade Type;
- Fast Acting Mfr.: Littelfuse 0287030 or equivalent
|
Environment |
Operating Temperature Range | -20°C to +40°C / -4°F to +104°F |
Storage Temperature | 30°C to +70°C / -22°F to +158°F |
Relative Humidity | Up to 90%, non condensing |
Operating Conditions | Indoor, ventilated, cool and dust free |
Compliance |
Safety | Intertek-ETL Listed as folLows:- Conforms to UL STD. 1564
- Certified to CSA STD. C22.2 No. 107.2
|
EMI | FCC Part 15(B), Class B |
Dimensions |
L x W x H | 331 x 244 x 97 mm / 13.03 x 9.61 x 3.82 in |
Weight | 4.1 kg / 9.0 lbs |