| Conditions Input impedance, Zi | 100 Hz, -10 dBV, test circuit 1 |
| Typical Input impedance, Zi | 39.4 kΩ |
| Conditions Insertion loss | 100 Hz, -10 dBV, test circuit 1 |
| Typical Insertion loss | 0.00 dB |
| Conditions Magnitude response, ref 1 kHz | 2 Hz, -10 dBV, test circuit 1 |
| Typical Magnitude response, ref 1 kHz | -0.11 dB |
| Conditions Magnitude response, ref 1 kHz | 2 kHz, -10 dBV, test circuit 1 |
| Typical Magnitude response, ref 1 kHz | -0.65 dB |
| Conditions Deviation from linear phase (DLP) | 10 Hz to 2 kHz, -10 dBV, test circuit 1 |
| Typical Deviation from linear phase (DLP) | +0.7/-0 |
| Conditions Distortion (THD) | 100 Hz, -10 dBV, test circuit 1 |
| Typical Distortion (THD) | <0.001% |
| Conditions Distortion (THD) | 20 Hz, -10 dBV, test circuit 1 |
| Typical Distortion (THD) | 0.01% |
| Conditions Maximum 20 Hz input level | 1% THD, test circuit 1 |
| Typical Maximum 20 Hz input level | +18 dBV |
| Conditions Output impedance, Zo | 100 Hz, test circuit 1 |
| Typical Output impedance, Zo | 5.00 kΩ |