Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Iso-Max RCA to Cat5 TX/RX Extender
Iso-Max RCA to Cat5 TX/RX Extender
Iso-Max RCA to Cat5 TX/RX Extender
Jensen Transformers
Iso-Max RCA to Cat5 TX/RX Extender
Iso-Max RCA to Cat5 TX/RX Extender
Iso-Max RCA to Cat5 TX/RX Extender

Jensen Transformers CI-RJ2R-SET Iso-Max RCA to Cat5 TX/RX Extender

Part #:
CI-RJ2R-SET
Model #:
Iso-Max
Condition:
Brand New
Discontinued
Manufacturer warranty

Description

Discontinued

Technical details

Main features
  • Channels 2
  • Connectors Transmitter: 2 x RCA, female, unbalanced (inputs) 1 x Ethernet RJ45 (output) 1 x Ethernet RJ45 (expand) Receiver: 2 x RCA, female, unbalanced (outputs 1 x Ethernet RJ45 (input) 1 x Ethernet RJ45 (expand)
  • Dimensions 4.32 x 2.6 x 1.45" / 109.7 x 66.0 x 36.8 mm, each
  • Frequency Response 5 Hz to 20 kHz
  • Type Passive interface
  • Temperature Range 32 to 158°F / 0 to 70°C (Operation or storage)
  • Output Impedance 1 kHz: Typical: 5.3 kOhms
  • Input Impedance Zi, 1 kHz, -10 dBV: Typical: 22 kOhms
  • Maximum Input Level 1% THD: Minimum: +14 dBV Typical: +17 dBV
  • Voltage Gain 1 kHz, -10 dBV: Minimum: -2.0 dB Typical: -3.0 dB Maximum: -1 dB
  • Common Mode Rejection Ratio 60 Hz: Typical: 115 dB 3 kHz Minimum: 80 dB Typical: 90 dB
  • Distortion (THD) 1 kHz, +2 dBV: Typical: < 0.001% 20 Hz, +2 dBV Typical: 0.04% Maximum: 0.10%
  • Magnitude Response 20 Hz, -10 dBV: Minimum: -0.15 dB Typical: -0.03 dB Maximum: ± 0.0 dB 20 kHz, -10 dBV Minimum: -0.35 dB Typical: -0.20 dB Maximum: ± 0.0 dB
  • Deviation from Linear Phase 20 Hz to 20 kHz, -10 dBV: Typical: +1.4 / -0° Maximum: ± 2.0°
  • Optimal Cable Length 25' / 8 m (375 pF): Typical: 0 dB 50' / 15 m (750 pF) Typical: 0 dB 100' / 30 m (1.5 nF) Typical: -0.2 dB 250' / 80 m (3.75 nF) Typical: -1.0 dB 350' / 100 m (5.25 nF) Typical: -1.7 dB (Cable length effect on 20 kHz response in dB, cable at 15 pF per foot)
  • Voltage Difference Minimum: 250 V RMS (Transmitter-to-receiver ground references, 60 Hz, 1-minute test duration)