Product Characteristics |
Electrical Design | PNP/NPN; (configurable) |
Output Function | Normally open / closed; (configurable) |
Sensing Range [mm] | 250 - 2500; (Target: 400 x 400 mm) |
Communication Interface | IO-Link |
Housing | Threaded type |
Dimensions [mm] | M30 x 1.5 / L = 103 |
Electrical Data |
Operating Voltage [V] | 10 - 30 DC |
Current Consumption [mA] | < 50 |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | < 0.5 |
Converter frequency [kHz] | 112 |
Inputs / Outputs |
Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
Outputs |
Total Number of Outputs | 2 |
Electrical Design | PNP/NPN; (configurable) |
Number of Digital Outputs | 1 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.2 |
Permanent Current Rating of Switching Output DC [mA] | 100 |
Switching Frequency DC [Hz] | 1 |
Number of Analog Outputs | 1 |
Analog Voltage Output [V] | 0 - 10 |
Minimum Load Resistance [Ω ] | 3000 |
Short-Circuit Protection | Yes |
Overload Protection | Yes |
Monitoring Range |
Sensing Range [mm] | 250 - 2500; (Target: 400 x 400 mm) |
Blind zone [mm] | 250 |
Angle of Aperture Cylindrical [° ] | 12; (± 2) |
Maximum deviation from the 90° angle sensor/object [° ] | ± 4 |
Accuracy / Deviations |
Temperature compensation | Yes |
Hysteresis [%] | < 3 |
Linearity error of analog output [%] | < 3 |
Temperature Drift | ± 5 %; (of the final value of the measuring range) |
Repeatability | 1 % |
Resolution [mm] | 3 |
Notes on the Accuracy / Deviation | The indicated values are reached after a warm-up time of min. 20 minutes |
Reaction Times |
Response Time [s] | Analog output |
Response Time [ms] | < 600 |
Software / Programming |
Parameter Setting | Hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel |
SIO Mode | Yes |
Required Master Port Class | A |
Minimum Process Cycle Time [ms] | 3.2 |
IO-Link Functions (Acyclical) | Application specific tag; operating hours counter |
Operating Conditions |
Ambient Temperature [° C] | -10 - 60 |
Storage Temperature [° C] | -15 - 65 |
Protection | |
MTTF [Years] | 108 |
Mechanical Data |
Weight [g] | 259.6 |
Housing | Threaded type |
Dimensions [mm] | M30 x 1.5 / L = 103 |
Thread Designation | M30 x 1.5 |
Material | Stainless steel (1.4404 / 316L); LED window: TPU (urethane); potting: PUR |
Tightening Torque [Nm] | 100 |