| Product Characteristics |
| Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
| Process Connection | Threaded connection G 1 DN25 flat seal |
| System | Gold-plated contacts |
| Application | Totalizer function; for industrial applications |
| Installation | Connection to pipe by means of an adapter |
| Media | Conductive liquids; water; water-based media |
| Medium Temperature [° C] | -10 - 70 |
| Pressure Rating [bar] | 16 |
| Pressure Rating [MPa] | 1.6 |
| MAWP (for Applications According to CRN) [bar] | 11.2 |
| Electrical Data |
| Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
| Current Consumption [mA] | 95; (24 V) |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | 5 |
| Inputs / Outputs |
| Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
| Inputs |
| Inputs | Counter reset |
| Outputs |
| Total Number of Outputs | 2 |
| Output Signal | Switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Electrical Design | PNP/NPN |
| Number of Digital Outputs | 2 |
| Output Function | Normally open / closed; (configurable) |
| Maximum Voltage Drop Switching Output DC [V] | 2 |
| Permanent Current Rating of Switching Output DC [mA] | 200 |
| Number of Analog Outputs | 1 |
| Analog Current Output [mA] | 4 - 20; (scalable) |
| Maximum Load [Ω ] | 500 |
| Analog Voltage Output [V] | 0 - 10; (scalable) |
| Minimum Load Resistance [Ω ] | 2000 |
| Pulse output | Flow rate meter |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Yes (non-latching) |
| Overload Protection | Yes |
| Measuring/Setting Range |
| Volumetric flow quantity monitoring |
| Pulse value | 0.00001 - 100 000 m³ |
| Pulse length [s] | 0,0025 - 2 |
| Temperature Monitoring |
| Measuring Range [° C] | -20 - 80 |
| Resolution [° C] | 0.2 |
| Set point SP [° C] | -19.2 - 80 |
| Reset point rP [° C] | -19.6 - 79.6 |
| Analog Start Point [° C] | -20 - 60 |
| Analog End Point [° C] | 0 - 80 |
| In Steps of [° C] | 0.2 |
| Accuracy / deviations Flow monitoring |
| Accuracy (in the Measuring Range) | ± (0,8 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2% MEW |
| Temperature Monitoring |
| Accuracy [K] | ± 2,5 (Q>5 l/min) |
| Reaction Times Flow monitoring |
| Response Time [s] | 0.15; (dAP = 0, T19) |
| Delay Time Programmable dS, dr [s] | 0 - 50 |
| Damping Process Value dAP [s] | 0 - 5 |
| Temperature Monitoring |
| Dynamic Response T05 / T09 [s] | T09 = 20 (Q>5 l/min) |
| Software / Programming |
| Parameter Setting | Flow monitoring; quantity meter; Preset counter; Temperature Monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display Unit |
| Interfaces |
| Communication Interface | IO-Link |
| Transmission Type | COM2 (38,4 kBaud) |
| IO-Link Revision | 1.1 |
| SDCI Standard | IEC 61131-9 |
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO Mode | Yes |
| Required Master Port Class | A |
| Process Data Analog | 3 |
| Process Data Binary | 2 |
| Minimum Process Cycle Time [ms] | 5 |
| Operating Conditions |
| Ambient Temperature [° C] | -10 - 60 |
| Storage Temperature [° C] | -25 - 80 |
| Protection | IP 67 |
| MTTF [Years] | 145 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Mechanical Data |
| Weight [g] | 640 |
| Material | Stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
| Materials (Wetted Parts) | - Stainless steel (1.4404 / 316L)
- PEEK
- EPDM
|
| Process Connection | Threaded connection G 1 DN25 flat seal |
| Electrical Connection |
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |