Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Magnetic-Inductive 80 - 9600 gph Flow Meter
Magnetic-Inductive 80 - 9600 gph Flow Meter
Magnetic-Inductive 80 - 9600 gph Flow Meter
IFM
Magnetic-Inductive 80 - 9600 gph Flow Meter
Magnetic-Inductive 80 - 9600 gph Flow Meter
Magnetic-Inductive 80 - 9600 gph Flow Meter

IFM SM2001 Magnetic-Inductive 80 - 9600 gph Flow Meter

Brand: IFM
Part #:
SM2001
Model #:
SMR21XGXFRKG/US
Condition:
Brand New

Choose Measuring Range (gph)

$1,370.00 /Each
Free shipping
Typically In Stock
Check availability
$1,370.00 /Each
Manufacturer warranty

Description

$1,370.00 /Each
Free shipping
Typically In Stock
Check availability

Technical details

Main features
  • Inputs Counter reset
  • Material Stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
  • Application Totalizer function; empty pipe detection; for industrial applications
  • System Gold-plated contacts
  • Output Signal Switching signal; analog signal; pulse signal; frequency signal; IO-Link; (configurable)
  • Communication Interface IO-Link
  • Protection Class III
  • Number of Digital Outputs 2
  • Installation Connection to pipe by means of an adapter
  • Process Connection Threaded connection G 2 DN50 flat seal
  • Output Function Normally open / closed; (configurable)
  • Measuring Range (gph) 80 - 9600
  • Electrical Design PNP/NPN
  • Protection IP 65 IP 67
  • Overload Protection Yes
  • Repeatability ± 0,2% MEW
  • Short-circuit protection Yes
  • Pulse Output Flow rate meter
  • Operating voltage [V] 18 - 32 DC; (to SELV/PELV)
  • Media Conductive liquids; water; water-based media
  • Temperature Drift ± 0,0185 ° F / K
  • Reverse Polarity Protection Yes
  • Current Consumption [mA] < 150
  • Analog Current Output [mA] 4 - 20; (scalable)
  • Maximum Load [Ω ] 500
  • MTTF [Years] 85
  • Weight [g] 3069.2
  • Total Number of Outputs 2
  • Number of Analog Outputs 1
  • Analog Voltage Output [V] 0 - 10; (scalable)
  • Minimum Load Resistance [Ω ] 2000
  • Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
  • Materials (Wetted Parts) Stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM
  • Pressure rating [psi] 232
  • Maximum Voltage Drop Switching Output DC [V] 2
  • Power-on Delay Time [s] 5
  • Response Time [s] 0.35; (dAP = 0)
  • Medium temperature [° F] 14 - 194
  • Pressure Rating [bar] 16
  • Ambient Temperature [° F] 14 - 140
  • Storage Temperature [° F] -13 - 176
  • Permanent Current Rating of Switching Output DC [mA] 250; (per output)
  • MAWP (for Applications According to CRN) [bar] 16
  • Frequency of the output [Hz] 0.1 - 10000
  • Measuring dynamics 1: 120
  • Accuracy (in the Measuring Range) ± (0,8 % MW + 0,5 % MEW)
  • Accuracy [K] ± 1 (77 ° F; Q>4 gpm)
  • Damping Process Value dAP [s] 0 - 5
  • Dynamic Response T05 / T09 [s] T09 = 3 (Q>4 gpm)
  • Parameter Setting Flow monitoring; quantity meter; Preset counter; Temperature Monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/frequency/pulse output; Start-up delay; display can be deactivated; Display Unit; empty pipe detection
  • Transmission Type COM2 (38,4 kBaud)
  • IO-Link Revision 1.1
  • SDCI Standard IEC 61131-9 CDV
  • Profiles Smart Sensor: Process Data Variable; Device Identification
  • SIO Mode Yes
  • Required Master Port Class A
  • Process Data Analog 3
  • Process Data Binary 2
  • Minimum Process Cycle Time [ms] 5
  • Type of Short-Circuit Protection Yes (non-latching)
  • Pulse value 0.02 - 160 E06 gal
  • In steps of 0.02 gal
  • Pulse length [s] 0,008 - 2
  • Measuring range [° F] -4 - 176
  • Display range [° F] -40 - 212
  • Resolution [° F] 0.5
  • Set point SP [° F] -2 - 176
  • In steps of [° F] 0.5
  • Delay Time Programmable dS, dr [s] 0 - 50
  • Reset point rP [° F] -3 - 175
  • Analog start point [° F] -4 - 140
  • Analog end point [° F] 32 - 176