Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Calorimetric Flow Sensor with 100mm Probe
Calorimetric Flow Sensor with 100mm Probe
Calorimetric Flow Sensor with 100mm Probe
Calorimetric Flow Sensor with 100mm Probe
IFM
Calorimetric Flow Sensor with 100mm Probe
Calorimetric Flow Sensor with 100mm Probe
Calorimetric Flow Sensor with 100mm Probe
Calorimetric Flow Sensor with 100mm Probe

IFM SA4300 Calorimetric Flow Sensor with 100mm Probe

Brand: IFM
Part #:
SA4300
Model #:
SAEXXXXBFRKG/US-100
Condition:
Brand New

Choose Probe Length (mm)

$542.00 /Each
Free shipping
Typically In Stock
Check availability
$542.00 /Each
Manufacturer warranty

Description

$542.00 /Each
Free shipping
Typically In Stock
Check availability

Technical details

Main features
  • Material Stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30
  • Accuracy ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions: ; water: 20 - 70 ° C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)
  • System Gold-plated contacts
  • Output Signal Switching signal; analog signal; frequency signal; IO-Link; (configurable)
  • Communication Interface IO-Link
  • Protection Class III
  • Number of Digital Outputs 2
  • Process Connection Diameter Ø 8 mm
  • Output Function Normally open / closed; (configurable)
  • Probe Length (mm) 100
  • Electrical Design PNP/NPN
  • Operating Mode Relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory Setting: relative)
  • Protection IP 65 IP 67
  • Connection Connector: 1 x M12; coding: A; Contacts: gold-plated
  • Overload Protection Yes
  • Repeatability 0,05 m/s; (water; Flow velocity: 0,05 - 3 m/s)
  • Short-circuit protection Yes
  • Operating voltage [V] 18 - 30 DC
  • Media Water; glycol solutions; air; oils
  • Temperature Drift ± 0,005 K/° C
  • Reverse Polarity Protection Yes
  • Current Consumption [mA] < 100
  • Analog Current Output [mA] 4 - 20; (scalable)
  • Maximum Load [Ω ] 350
  • Ambient Temperature [° C] -40 - 80
  • Storage Temperature [° C] -40 - 100
  • MTTF [Years] 180
  • Weight [g] 345.5
  • Medium Temperature [° C] -20 - 100
  • Total Number of Outputs 2
  • Number of Analog Outputs 1
  • Materials (Wetted Parts) Stainless steel (1.4404 / 316L)
  • Maximum Voltage Drop Switching Output DC [V] 2.5
  • Power-on Delay Time [s] 10
  • Response Time [s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
  • Pressure Rating [bar] 50
  • Pressure Rating [MPa] 5
  • Permanent Current Rating of Switching Output DC [mA] 250
  • MAWP (for Applications According to CRN) [bar] 50
  • Frequency of the output [Hz] 0 - 1000
  • Measuring Range [° C] -20 - 100
  • Resolution [° C] 0.2
  • Accuracy [K] ± 0,3 / ± 1; (water; Flow velocity: 0,3 - 3 m/s / air; Flow velocity: >10 m/s)
  • Dynamic Response T05 / T09 [s] 1,5 (T09); (water; Flow velocity: 0,3 - 3 m/s)
  • Parameter Setting Hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color
  • Transmission Type COM2 (38,4 kBaud)
  • IO-Link Revision 1.1
  • SDCI Standard IEC 61131-9
  • Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
  • SIO Mode Yes
  • Required Master Port Class A
  • Process Data Analog 2
  • Process Data Binary 2
  • Minimum Process Cycle Time [ms] 3
  • Type of Short-Circuit Protection Yes (non-latching)
  • Probe Length L [mm] 200
  • Temperature Drift [cm/s x 1/K] 0,003 m/s x 1/K (<20 ° C; >70 ° C)
  • Maximum Temperature Gradient of Medium [K/min] 100
  • Setting Range [m/s] 0 - 100, 0 - 200, 0.04 - 3, 0.04 - 6
  • Greatest Sensitivity [m/s] 0.04 - 3, 30 - 100

Related items.

Customers buy together with this.

Reviews.

There are currently no reviews for this product. You can leave the first review and share your experience.