Welcome to the New PrimeBuy.comWe've upgraded our store to make finding and ordering the equipment you need faster and easier.Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page.If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed.Thank you for choosing PrimeBuy
MaterialHousing: diecast zinc; front lens: plastics
Communication InterfaceIO-Link
Protection ClassIII
Number of Digital Outputs2
Output FunctionNormally open / closed; (configurable)
Electrical DesignPNP/NPN; (configurable)
Type of LightRed light
Measuring Range IO-Link (mm)1
ProtectionIP 65 IP 67
ConnectionConnector: 1 x M12; coding: A
HousingRectangular
Operating Distance (m)2
Overload ProtectionYes
Short-circuit protectionYes
Number of digital inputs1
Operating voltage [V]10 - 30 DC; (cULus - Class 2 source required)
Reverse Polarity ProtectionYes
Temperature CompensationYes
Current Consumption [mA]<60
MTTF [Years]572
Weight [g]127
Tightening Torque [Nm]5
Number of Inputs and OutputsNumber of Digital Inputs: 1 Number of Digital Outputs: 2
Total Number of Outputs2
Maximum Voltage Drop Switching Output DC [V]2.2
Dimensions [mm]51 x 51 x 17
Power-on Delay Time [s]<0.3
Permanent Current Rating of Switching Output DC [mA]100
Parameter SettingHysteresis / window / 2-point; Switch-on and switch-off delay; switch-on operations; Teach function; filter; light-on/dark-on mode; laser switch-off; Type of Operation
Transmission TypeCOM2 (38,4 kBaud)
IO-Link Revision1.1
SDCI StandardIEC 61131-9
ProfilesMeasuring and Switching Sensor, 1 channel, Identification and Diagnosis, Sensor Control, Teach two value, Locator, ProductURI
SIO ModeYes
Required Master Port ClassA
Minimum Process Cycle Time [ms]3.2
Ambient Temperature [°C]0 - 60
Storage Temperature [°C]-10 - 65
Switching Frequency DC [Hz]200
Resolution [mm]0,05
Repeatability [mm]0.1
Notes on the Accuracy / DeviationThe indicated values are reached after a warm-up time of 20 minutes.
IO-Link Functions (Acyclical)Application specific tag; operating hours counter
Wave Length [nm]630
Range adjustableYes
Maximum light spot diameter [mm]1
Light spot dimensions refer toAt maximum range
Laser Protection Class1
Teach functionYes
Typ. lifetime [h]50000
Measuring Range [m]0.05 - 0.2; (6 - 90% remission)
Related items.
Customers buy together with this.
Reviews.
There are currently no reviews for this product. You can leave the first review and share your experience.