| Product Characteristics |
| Type of Light | Red light |
| Laser Protection Class | 1 |
| Housing | Rectangular with M18 thread |
| Electrical Data |
| Operating Voltage [V] | 18 - 30 DC; (cULus - Class 2 source required) |
| Current Consumption [mA] | 45; (24 V) |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Type of Light | Red light |
| Wave Length [nm] | 650 |
| Inputs / Outputs |
| Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
| Inputs |
| Inputs | Laser On/ Off |
| Outputs |
| Total Number of Outputs | 2 |
| Electrical Design | PNP/NPN; (configurable) |
| Number of Digital Outputs | 2 |
| Output Function | 2 x normally open / normally closed; (configurable) |
| Maximum Current Load per Output [mA] | 100 |
| Number of Analog Outputs | 1 |
| Analog Current Output [mA] | 4 - 20; (IEC 61131-2) |
| Maximum Load [Ω] | 250 |
| Analog Voltage Output [V] | 0 - 10; (IEC 61131-2) |
| Minimum Load Resistance [Ω] | 5000 |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Yes (non-latching) |
| Overload Protection | Yes |
| Operating Mode: FINE |
| Switching Frequency DC [Hz] | 20 |
| Operating Mode: STD |
| Switching Frequency DC [Hz] | 40 |
| Operating Mode: FAST |
| Switching Frequency DC [Hz] | 60 |
| Monitoring Range |
| Maximum light spot diameter [mm] | 5 |
| Light spot dimensions refer to | At maximum range |
| Background suppression [m] | <20 |
| Measuring/Setting Range |
| Setting Range object reflectivity [%] | 6 - 900; (reflectivity; 6 % black paper; 100 % white paper) |
| Operating Mode: FINE |
| Measuring Range [m] | 0.05 - 2 |
| Sampling rate [Hz] | 60 |
| Operating Mode: STD |
| Measuring Range [m] | 0.05 - 2 |
| Sampling rate [Hz] | 120 |
| Operating Mode: FAST |
| Measuring Range [m] | 0.05 - 1 |
| Sampling rate [Hz] | 180 |
| Software / Programming |
| Parameter Setting | Distance / reflectivity; hysteresis / window; Sensitivität; current/voltage output; Sequence modulation to avoid mutual interference by similar sensors |
| Interfaces |
| Communication Interface | IO-Link |
| Transmission Type | COM2 (38,4 kBaud) |
| IO-Link Revision | 1.1.3 |
| SDCI Standard | IEC 61131-9 |
| Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
| SIO Mode | Yes |
| Required Master Port Class | A |
| Minimum Process Cycle Time [ms] | 5 |
| IO-Link Functions (Acyclical) | Application specific tag; operating hours counter; switching cycles counter |
| Operating Conditions |
| Ambient Temperature [°C] | -25 - 50 |
| Storage Temperature [°C] | -30 - 80 |
| Protection | |
| Laser Protection Class | 1 |
| MTTF [Years] | 258 |
| Mechanical Data |
| Weight [g] | 53.4 |
| Housing | Rectangular with M18 thread |
| Dimensions [mm] | 61.7 x 22.5 x 45.2 |
| Thread Designation | M18 x 1 |
| Material | - Housing: PPSU; ABS; PMMA; PBT / PC; EPDM
- Front lens: PMMA
|
| Lens alignment | Side sensing |