| Product Characteristics |
| Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
| Process Connection | G 1 Aseptoflex Vario |
| System | gold-plated contacts |
| Dielectric Constant of the Medium | ≥ 2 |
| Recommended Media | Water; water-based media |
| Medium Temperature [°C] | -40 - 150 |
| Maximum Speed of the Change of Level [mm/s] | 200 |
| Pressure Rating [bar] | 8 |
|
| Vacuum Resistance [mbar] | -1000 |
| MAWP (for Applications According to CRN) [bar] | 8 |
| Radio Approval for | EU/RED; United Kingdom; South Korea; USA; Canada; Australia; New Zealand; Vietnam |
| Electrical Data |
| Operating Voltage [V] | 18 - 30 DC |
| Current Consumption [mA] | <80 |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | <15 |
| Measuring Principle | FMCW (80 GHz technology); frequency range 77 - 81 Hz |
| Inputs / Outputs |
| Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
| Outputs |
| Total Number of Outputs | 2 |
| Output Signal | Switching signal; analog signal; IO-Link |
| Electrical Design | PNP/NPN |
| Number of Digital Outputs | 1; (2 configurable) |
| Output Function | Normally open / closed; (configurable) |
| Maximum Voltage Drop Switching Output DC [V] | 2.5 |
| Permanent Current Rating of Switching Output DC [mA] | 50 |
| Number of Analog Outputs | 1 |
| Analog Current Output [mA] | 4 - 20, invertible; (scalable) |
| Maximum Load [Ω] | 43,5 * (Ub - 18) + 600 Ω |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Yes (non-latching) |
| Overload Protection | Yes |
| Measuring/Setting Range |
| Measuring Range [m] | 10 |
| Sampling rate [Hz] | >3 |
| Accuracy / Deviations |
| Resolution [mm] | 1 |
| Zero Signal (Current) [mA] | 3.8 |
| Full Signal (Current) [mA] | 20.5 |
| Temperature Drift per 10 K | ± 1 mm |
| Reaction Times |
| Response Time [ms] | 330 |
| Interfaces |
| Communication Interface | IO-Link |
| Transmission Type | COM2 (38,4 kBaud) |
| IO-Link Revision | 1.1 |
| SDCI Standard | IEC 61131-9 |
| Profiles | Smart Sensor ED2: SSCs (0x8001), Measuring Sensor (0x000A) |
| SIO Mode | Yes |
| Required Master Port Class | A |
| Process Data Analog | 1 |
| Process Data Binary | 2 |
| Minimum Process Cycle Time [ms] | 6 |
| Operating Conditions |
| Ambient Temperature [°C] | -40 - 80 |
| Storage Temperature [°C] | -40 - 90 |
| Protection | IP 68; IP 69K |
| MTTF [Years] | 330 |
| Mechanical Data |
| Weight [g] | 727.15 |
| Material | - Stainless steel (1.4404 / 316L)
- PA
- FKM
- FVMQ
|
| Materials (Wetted Parts) | PTFE; EPDM |
| Process Connection | G 1 Aseptoflex Vario |
| Surface characteristics Ra/Rz of the wetted parts | <0.76 |
| Notes | An IO-Link master and a parameter setting software (e.g. moneo or LR DEVICE) are required for initial set-up. |
| Electrical Connection |
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |