| Product Characteristics |
| Number of Inputs and Outputs | Number of Analog Outputs: 1 |
| Probe Length L [mm] | 100 - 1600 |
| Process Connection | Threaded connection G 3/4 external thread |
| System | gold-plated contacts |
| Media | Liquids |
| Dielectric Constant of the Medium | ≥ 1,8; (for media with a dielectric constant of 1.8 - 5 (e.g. oils), a coaxial pipe is needed for operation) |
| Recommended Media | Water; water-based media; oils; oil-based media |
| Process temperature [°C] | -25 - 80; (90<1 h) |
| Pressure Rating [bar] | 16 |
| Vacuum Resistance [mbar] | -1000 |
| MAWP (for Applications According to CRN) [bar] | 16 |
| Electrical Data |
| Operating Voltage [V] | 18 - 30 DC |
| Current Consumption [mA] | <25 |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | <3 |
| Measuring Principle | guided wave radar |
| Inputs / Outputs |
| Number of Inputs and Outputs | Number of Analog Outputs: 1 |
| Outputs |
| Total Number of Outputs | 2 |
| Output Signal | Analog signal; IO-Link |
| Electrical Design | PNP |
| Number of Analog Outputs | 1 |
| Analog Current Output [mA] | 4 - 20, invertible |
| Maximum Load [Ω] | 500 |
| Analog Voltage Output [V] | 0 - 10, invertible |
| Minimum Load Resistance [Ω] | 2000 |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Thermal, pulsed |
| Overload Protection | Yes |
| Measuring/Setting Range |
| Probe Length L [mm] | 100 - 1600 |
| Active Range A [mm] | L-40; (when set to oil and oil based media: L-60) |
| Inactive Range I1 / I2 [mm] | 30 / 10; (when set to oil and oil based media: 30 / 30) |
| Sampling rate [Hz] | 4 |
| Accuracy / Deviations |
| Repeatability [mm] | ± 5 |
| Measuring Error [mm] | ± 7 |
| Offset Error [mm] | 5 |
| Resolution [mm] | 1 |
| Zero Signal (Voltage) [V] | 0 |
| Zero Signal (Current) [mA] | 4 |
| Full Signal (Voltage) [V] | 10 |
| Full Signal (Current) [mA] | 20 |
| Temperature Drift per 10 K | ± 0.2 % |
| Interfaces |
| Communication Interface | IO-Link |
| Transmission Type | COM2 (38,4 kBaud) |
| IO-Link Revision | 1.1 |
| SDCI Standard | IEC 61131-9 CDV |
| Profiles | No profile |
| SIO Mode | No |
| Required Master Port Class | A |
| Process Data Analog | 1 |
| Minimum Process Cycle Time [ms] | 2.3 |
| Operating Conditions |
| Ambient Temperature [°C] | -25 - 60 |
| Storage Temperature [°C] | -40 - 85 |
| Protection | IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68) |
| MTTF [Years] | 239 |
| Mechanical Data |
| Weight [g] | 470.9 |
| Material | - Stainless steel (1.4301 / 304)
- Stainless steel (1.4404 / 316L)
- FKM
- PEI
|
| Materials (Wetted Parts) | - Stainless steel (1.4305 / 303)
- Probe connection: stainless steel (1.4435 / 316L)
- PTFE
- FKM
- Sealing: NBR fiber-reinforced
|
| Process Connection | Threaded connection G 3/4 external thread |
| Notes | For high process temperatures: The temperature at the Process Connection is decisive. The actual medium temperature may be higher. |
| Electrical Connection |
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |