Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

FC Solar Clamp Meter CAT III 1500 V
FC Solar Clamp Meter CAT III 1500 V
FC Solar Clamp Meter CAT III 1500 V
FC Solar Clamp Meter CAT III 1500 V
FC Solar Clamp Meter CAT III 1500 V
Fluke
FC Solar Clamp Meter CAT III 1500 V
FC Solar Clamp Meter CAT III 1500 V
FC Solar Clamp Meter CAT III 1500 V
FC Solar Clamp Meter CAT III 1500 V
FC Solar Clamp Meter CAT III 1500 V

Fluke FLUKE-393 FC FC Solar Clamp Meter CAT III 1500 V

Brand: Fluke
Part #:
FLUKE-393 FC
Condition:
Brand New
$883.00 /Each
Typically In Stock
Check availability
$883.00 /Each
Manufacturer warranty

Description

$883.00 /Each
Typically In Stock
Check availability

Technical details

Main features
  • Dimensions Size: 11.06 x 3.3 x 1.92" (281 x 84 x 49 mm) Jaw opening: 1.33" (34 mm) Flexible current probe diameter: 0.29" (7.5 mm) Flexible current probe cable length (head to electronics connector): 0.07" (1.8 m)
  • Display Dual display with backlight
  • Temperature Operating: 14 to 122°F (-10 to 50°C) Storage: -40 to 140°F (-40 to 60°C)
  • Operating Humidity Non-condensing <50°F (10°C) ≤90% RH at 50 to 86°F (10 to 30°C) ≤75% RH at 86 to 104°F (30 to 40°C) ≤45% RH at 104 to 122°F (40 to 50°C)
  • Altitude Operating: 6561.68' (2000 m) Storage: 39,370.07' (12,000 m)
  • Safety General: IEC 61010-1, Pollution Degree 2 Measurement: IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
  • DC power Range: 600 kVA (600 V DC range), 1500 kVA (1500 V DC range) Resolution: 0.1 kVA, 1 kVA Accuracy: 2% RD + 2 kVA, 2% RD + 20 kVA
  • Resistance Range: 600 Ω, 6000 Ω, 60 kΩ Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60 kΩ) Accuracy: 1% RD + 5 digits
  • Batteries Two AA IEC LR6 alkaline
  • Automatic Power Off 20 Minutes
  • DC Voltage Range: 600 V; 1500 Resolution: 0.1 V (≤600 V), 1 V (≤1500 V) Accuracy: 1% RD + 5 digits
  • Capacitance Range: 100 μF, 1000 μF Resolution: 0.1 μF (≤100 μF), 1 μF (≤1000 μF) Accuracy: 1% RD + 5 digits Inrush trigger level: 5 A
  • AC Voltage Range: 600 V; 1000 V Resolution: 0.1 V (≤600 V); 1 V (≤1000 V) Accuracy: 1% RD + 5 digits (20 to 500 Hz)
  • DC Current Range: 999.9 A Resolution: 0.1 A Accuracy: 2% RD + 5 digits, When using the ZERO function to compensate for offsets
  • Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
  • Wireless Radio Radio frequency certification: FCC ID: T68-FBLE, IC: 6627A-FBLE Wireless radio frequency range: 2400 to 2483.5 MHz Output power: <100 mW SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product complies with Directive 2014/53/EU.
  • Maximum Voltage Between Any Terminal and Earth Ground 1000 V AC 1500 V DC
  • Position sensitivity Distance from optimum: A B C i2500-18 Flex: 1.4" (35.6 mm) 2" (50.8 mm) 2.5" (63.5 mm) Error: ±0.5% ±1% ±2%
  • Electrical Specifications Accuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 64.4 to 82.4°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) Temperature coefficients: Add 0.1 x specified accuracy for each °C > 64.4°F (28°C) or <82.4°F (18°C)
  • AC Current: Jaw Range: 999.9 A Resolution: 0.1 A Accuracy: 2% + 5 digits (10 to 100 Hz); 2.5% + 5 digits (100 to 500 Hz) Crest factor (50/60 Hz): 2.5 at 600 A 3 at 500 A 1.42 at 999.9 A Add 2% for C.F. >2
  • AC Current: Flexible Current Probe Range: 999.9 A; 2500 A Resolution: 0.1 A (≤999.9 A); 1 A (≤2500 A) Accuracy: 3 % RD + 5 digits (10 to 500 Hz) Crest factor (50/60Hz): 2.5 at 1400 A 3 at 1100 A 1.42 at 2500 A Add 2% for C.F. >2
  • mV DC Range: 500 mV Resolution: 0.1 mV Accuracy: 1% RD + 5 digits
  • Amps Frequency: Jaw Range: 5 to 500 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 to 10 Hz ≥10 A 10 to 100 Hz, ≥5 A 100 to 500 Hz, ≥10 A
  • Amps Frequency: Flexible Current Probe Range: 5 to 500 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 to 10 Hz ≥10 A 10 to 100 Hz, ≥5 A 100 to 500 Hz, ≥10 A
  • Voltage Frequency Range: 5 to 500 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 to 20 Hz, ≥5 V 20 to 100 Hz, ≥5 V 100 to 500 Hz, ≥10 V
  • Weight (With Batteries) 1.14 lbs (520 g)