| Current Measurement |
| Measuring Range | 0 to 2000 A DC or 1400 AC RMS |
| Autorange Facility | 40 A/400 A/2000 A |
| Resolution | - 10 mA in 40 A range
- 100 mA in 400 A range
- 1 in 2000 A range
|
| Accuracy |
| DC and DC RMS | - I > 10 A: ±1.5% rdg ±5 digits
- I < 10 A: ±0.2 A
|
| AVG | - I > 10 A: ±3% rdg ±5 digits
- I < 10 A: ±0.5 A
|
| Pk | - I > 10 A: ±5% rdg ±5 digits
- I < 10 A: ±0.5 A
|
| AHr | - I > 10 A: ±2% rdg ±5 digits
- I < 10 A: ±0.5 AHr
|
| CF (Crest Factor) | - 1.1 ≤ CF < 3: ±3% rdg ±5 digits
- 3 ≤ CF < 5: ±5% rdg ± 5 digits
- Resolution: 0.01
|
| RPL (Ripple) | - 2% ≤ RPL < 100%: ±3% rdg ±5 digits
- 100% ≤ RPL < 600%: ±5% rdg ± 5 digits
- Resolution: 0.01%
|
| Voltage Measurement |
| Measuring Range | 0 to 825 V DC or AC RMS |
| Autorange Facility | 4 V/40 V/400 V/750 V |
| Resolution | - 1 mV in 4 V range
- 10 mV in 40 V range
- 100 mV in 400 V range
- 1 V in 750 V range
|
| DC and DC RMS | - V > 1 V: ±1% rdg ±5 digits
- V < 1 V: ± 0.02 V
|
| AVG | - V > 1 V: ±3% rdg ±5 digits
- V < 1 V: ± 0.03 V
|
| Pk | - V > 1 V: ±5% rdg ±5 digits
- V < 1 V: ± 0.03 V
|
| CF (Crest Factor) | - V > 1 V: ±5% rdg ±5 digits
- V < 1 V: ±5% rdg ± 5 digits
- Resolution: 0.01
|
| RPL (Ripple) | - 2% ≤ RPL < 100%: ±3% rdg ± 5 digits
- 100% ≤ RPL < 600%: ±5% rdg ± 5 digits
- Resolution: 0.1%
|
| Harmonics |
| THD (Total Harmonic Distortion) | - 1% ≤ THD < 100%: ±3% rdg ± 5 digits
- 100% ≤ THD < 600%: ±5% rdg ± 5 digits
- Resolution: 0.1%
|
| DF (Distortion Factor) | - 1% ≤ DF < 100%: ±3% rdg ± 5 digits
- Resolution: 0.1%
- H02 ≤ Vharm< H13: ±5% rdg ± 2 digits
- H13 ≤ Vharm≤ H30: ± 10% rdg ± 2 digits
|
| Watts Measurement (Single - and Three-Phase) |
| Measuring Range | 0 to 1650 kW DC or 1200 kW AC |
| Autoranging Facility | 4, 40, 400, 1650 kW AC |
| Resolution | - 1 W in 4 kW
- 10 W in 40 kW
- 100 W in 400 kW
- 1 kW in 1200 kW
|
| Accuracy | - 2.5% rdg ± 5 digits
- W1Dia <2 kW ± 0.08 kW
- W3Dia <4 kW ± 0.25 kW
|
| VA Measurement (Single - and Three-Phase) |
| Measuring Range | 0 to 1650 kVA DC or 1200 kVA AC |
| Autorange Facility | 4, 40, 400, 1650 kVA |
| Resolution | - 1 VA in 4 kVA
- 10 VA in 40 kVA
- 100 VA in 400 kVA
- 1 kVA in 1200 kVA
|
| Accuracy | - VA >2 kVA: 2.5% rdg ± 5 digits
- VA <2 kVA: ±0.08 kVA
|
| VAR Measurement (Single - and Three-Phase) |
| Measuring Range | 0 to 1250 kVAR |
| Autorange Facility | 4, 40, 400, 1200 kVAR |
| Resolution | - 1 VAR in 4 kVAR
- 10 VAR in 40 kVAR
- 100 VAR in 400 kVAR
- 1 kVAR in 1200 kVAR
|
| Accuracy | - VA >4 kVAR: 2.5% rdg ± 5 digits
- VA <4 kVAR: ±0.25 kVAR
|
| Power Factor Range | 0.3 >PF <0.99 |
| Power Factor (Single - and Three-Phase) |
| Measuring Range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive) |
| Resolution | 0.001 |
| Accuracy | ±3° |
| Frequency Range | 15 Hz to 1 kHz |
| Displacement Power Factor |
| Measuring Range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive) |
| Resolution | 0.001 |
| Accuracy | ±3° |
| Frequency Range | 15 to 22 Hz and 45 to 65 Hz |
| Kilowatt Hour (kWHr) |
| Measuring Range | 40,000 kWHr |
| Autorange Facility | 1, 40, 400, 4000, 40,000 kWHr |
| Resolution | - 1 WHr in 4 kWHr
- 10 WHr in 40 kWHr
- 100 WHr in 400 kWHr
- 1 kWHr in 4,000 kWHr
- 10 kWHr in 40,000 kWHr
|
| Accuracy | - kWHr >2 kWHr: ±3% ± 5 digits
- kWHr <2 kWHr: ±0.08 kWHr
|
| All Watts /VA /VAR /PF Measurements | - Frequency range: DC and 15 Hz to 1 kHz
- Current range: 10 to 1400 A RMS
- Voltage range: 1 to 825 V RMS
- Maximum input: 825 V RMS/1400 A RMS
- Maximum overload: 1000 V RMS/10,000 A
|
| Frequency Measurement |
| Measuring Range | 15 Hz to 1 kHz |
| Resolution | 0.1 Hz |
| Accuracy | - 15 to 22 Hz ± 0.5% rdg
- 40 to 70 Hz ± 0.5% rdg
- 15 to 1000 Hz ± 1% rdg
|
| Current Range | 10 to 1400 A RMS |
| Voltage Range | 1 to 825 V RMS |
| Current Measurement |
| Ranges | 10/20/40/100/200/400/1000/2000 A |
| Resolution | - 1 A in 40 A
- 10 A in 400 A
- 50 A in 2000 A
|
| Accuracy | ±3% rdg ± 1 pixel |
| Maximum Overload | 10,000 A |
| Voltage Measurement |
| Ranges | 4/10/20/40/100/200/400/1000 V |
| Resolution | - 100 mV in 4 V
- 1 V in 40 V
- 10 V in 400 V
- 31.25 V in 1000 V
|
| Accuracy | ±2% rdg ± 1 pixel |
| Maximum Overload | 1000 V RMS |
| Frequency Range | DC and 15 to 600 Hz |
| Time Base | 2.5, 5, 10, 25, 50 ms/div |
| Refresh Rate | 0.5 seconds |
| Maximum Sampling Rate | 15.625 kHz |
| Inrush Current Function |
| Ranges | 40, 400, and 2000 A |
| Resolution | - 10 mA in 40 A range
- 100 mA in 400 A range
- 1 A in 2000 A range
|
| Accuracy | - I > 10 A: ±5% rdg ± 1 pixel
- I < 10 A: ±0.5 A
|
| Maximum Overload | Maximum overload 10,000 A or RMS x frequency <400,000 |
| Capture Time | 1, 3, 10, 30, 100, and 300 s |
| Maximum Sampling Rate | 15.625 kHz |
| Logging Memory |
| Logging Areas | Three areas that can be used individually or combined into one large area |
| Averaging Periods | 1, 2, 5, 10, 30 s, 1, 5, 10, 15 min, and custom |
| General |
| Display | Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
| Power Supply | Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
| Battery Life Typically | - >10 hours (backlight on full)
- >12 hours (backlight reduced)
|
| Battery Eliminator BE345 | - Input: 110/230 V, 50/60 Hz
- Output: 15 V DC, 300 mA
|
| Reference Conditions | All accuracies stated at 73.4 ± 1.8°F (23 ± 1°C) |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Temperature Coefficient of Current | ≤± 0.15% of rdg per °C |
| Temperature Coefficient of Voltage | ≤± 0.15% of rdg per °C |
| Maximum Relative Humidity | 80 % for temperatures up to 87°F (31°C) decreasing linearly to 50% relative humidity at 104°F (40°C) |
| Maximum Operating Altitude | 6561.7' (2000 m) |
| Mechanical |
| Cleaning | The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. |
| Jaw Capacity | 2.3" (58 mm) diameter |
| Jaw Opening | 2.4" (60 mm) |
| Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm |
| Weight | 1.8 lbs (820 g) with batteries |
| Electrical Safety |
| Maximum Safe Working Voltages | - Current measurement: 600 V AC RMS or DC between uninsulated conductor and ground
- Voltage measurement: 600 V AC RMS or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)
|