Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Fluke
Insulation Multimeter with Kit

Fluke FLUKE-1587/MDTFC Insulation Multimeter with Kit

Brand: Fluke
Part #:
FLUKE-1587/MDTFC
Condition:
Brand New
Contact Us For Pricing
Check availability
Contact Us For Pricing
Manufacturer warranty

Description

Contact Us For Pricing
Check availability

Technical details

Main features
  • Accuracy ±(2% + 3)
  • Range 400 mA, 60 mA
  • Measurement Range 0.01 MΩ to 2 GΩ
  • Included Multimeter / AC Current Clamp / Phase Rotation Indicator
  • Resolution 0.01 mA, 0.1 mA
  • Relative Humidity Noncondensing 0% to 95% at 10 °C to 30 °C (50 °F to 86 °F) 0% to 75% at 30 °C to 40 °C (86 °F to 104 °F) 0% to 40% at 40 °C to 55 °C (104 °F to 131 °F)
  • Overload Protection 1000 V RMS
  • Operating Temperature -20 °C to 55 °C (-4 °F to 131 °F)
  • Storage Temperature -40 °C to 60 °C (-40 °F to 140 °F)
  • Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
  • Response Time >1 m sec
  • Temperature Coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
  • Safety CAT IV 600 V, CAT III, 1000 V
  • Overload 600 mA for 2 minutes maximum
  • Open Circuit Voltage <8.0 V
  • Test Voltages 50, 100, 250, 500, 1000 V
  • Short circuit current 1.0 mA typical
  • Test voltage accuracy +20%, -0%
  • Auto discharge Discharge time <0.5 second for C = 1 µF or less
  • Maximum capacitive load Operable with up to 1 µF load
  • Maximum voltage applied to any terminal and common 1000 V
  • Radio frequency communication 2.4 GHZ ISM Band
  • Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
  • Accuracy ± (% of Rdg+Counts) ±(0.2% + 2), ±(1.5% + 2)
  • Burden voltage (Typical) 2 mV/mA
  • AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
  • Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
  • Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
  • Short-circuit test current 1 mA nominal
  • Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test