Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Fluke
Industrial ScopeMeter Hand-Held Oscilloscope

Fluke FLUKE-124B/NA Industrial ScopeMeter Hand-Held Oscilloscope

Brand: Fluke
Part #:
FLUKE-124B/NA
Condition:
Brand New
Contact Us For Pricing
Check availability
Contact Us For Pricing

Notification

warningWARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov

Manufacturer warranty

Description

Contact Us For Pricing
Check availability

Technical details

Main features
  • Weight 3.2 lbs (1.4 kg)
  • Dimensions 10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)
  • Frequency Range 15 Hz (1 Hz) to 50 MHz in continuous autoset
  • Accuracy ±(0.5% +5 counts), ±(0.5% +2 counts)
  • Package Includes without Fluke View Software
  • Temperature Battery Operation: 32 to 104°F (0 to 40°C) Power Adapter Operation: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C)
  • Storage Non-condensing at -4 to 140°F (-20 to 60°C)
  • Sensitivity 5 mV to 200 V/div
  • Safety General: IEC 61010-1: Pollution Degree 2 Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
  • Environmental MIL-PRF-28800F, Class 2
  • Input Impedance Without probes and test leads: 1 MΩ//20 pF With BB120: 1 MΩ//24 pF With STL120-IV 1:1 shielded test leads: 1 MΩ//230 pF With VP41 10:1 Probe: 5 MΩ//15.5 pF
  • Ranges 500 mV, 5 V, 50 V, 500 V, 750 V, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
  • Display Modes A, -A, B, -B
  • Full Scale Reading 10,000 counts, 5000 counts
  • Frequency Response - DC Coupled Without probes and test leads (with BB120): DC to 40 MHz (-3 dB) With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB)/DC to 20 MHz (-6 dB) With VP41 10:1 Probe: DC to 40 MHz (-3 dB)
  • Frequency Response - AC Coupled (LF Roll Off) Without probes and test leads: <10 Hz (-3 dB) With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB) With VP41 10:1 Probe: <10 Hz (-3 dB)
  • Rise Time, Excluding Probes, Test Leads <8.75 ns
  • Analog Bandwidth Limiter 10 kHz
  • Maximum Input Voltage A and B Direct, with test leads, or with VP41 Probe: 600 Vrms Cat IV, 750 Vrms maximum voltage With BB120: 600 Vrms
  • Maximum Floating Voltage, From any Terminal to Ground 600 Vrms Cat IV, 750 Vrms up to 400 Hz
  • Scope Modes Normal, Single, Roll
  • Ranges (Normal) Equivalent sampling: 10 to 500 ns/div Real time sampling: 1 µs to 5 s/div Single (real time): 1 µs to 5 s/div Roll (real time): 1s to 60 s/div
  • Sampling Rate (For Both Channels Simultaneously) Equivalent sampling (repetitive signals): Up to 4 GS/s Real time sampling 1 µs to 60 s/div: 40 MS/s
  • Common Mode Rejection (CMRR) >100 dB at DC >60 dB at 50, 60, or 400 Hz
  • Accuracy at 1 Hz to 1 MHz ±(0.5% +2 counts)
  • Maximum Reading 50.00 kRPM
  • Humidity (Operating) Non-condensing at 32 to 50°F (0 to 10°C) 95% at 50 to 86°F (10 to 30°C) 75% at 86 to 104°F (30 to 40°C) 45% at 104 to 122°F (40 to 50°C)
  • Wireless Radio with Adapter Frequency Range: 2412 to 2462 MHz Output power: <100 mW
  • Enclosure Protection IP51, ref: EN/IEC60529