Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Fluke
Multifunction Tester with US Plug

Fluke FLK-1663 US Multifunction Tester with US Plug

Brand: Fluke
Part #:
FLK-1663 US
Condition:
Brand New

Choose Plug Type

Contact Us For Pricing
Check availability
Contact Us For Pricing
Manufacturer warranty

Description

Contact Us For Pricing
Check availability

Technical details

Main features
  • Frequency 128 Hz
  • Output Voltage 25 V
  • Range 500 V, 10 Ω / 0.001 Ω / High current mΩ mode, 1000 A / 10 kA (50 kA), 200 Ω / 2000 Ω
  • Measurement Range RCD Type G: 310 ms, 50 ms
  • Resolution 0.1 V, 0.01 Ω / 0.1 Ω / 1 Ω, 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ, 1 A / 0.1 kA, 0.1 Ω / 1Ω
  • Plug Type US plug
  • Overload Protection 660 V rms
  • Current Range 30% to 110% of RCD rated current¹
  • Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
  • Performance EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition
  • Step Size 10% of IΔN²
  • Sealing IP-40
  • Size (L x W x H) 10 x 25 x 12.5 cm
  • Test Voltage 50 V 100 V 250 V 500 V 1000 V
  • Input Impedance 360 kΩ
  • Overvoltage CAT III / 500V; CAT IV 300V
  • Notes Responds to AC General, no delay Time delay Responds to pulsed signal Responds to smooth DC signal, 1000 mA type AC only 700 mA maximum type A in VAR mode, 30% to 150% for Type A IΔN > 10 mA 30% to 210% for Type A IΔN = 10 mA 20% to 210% for Type B
  • Measurement Accuracy ±5%
  • Open Circuit Voltage >4 V
  • Test Voltages 50-100-250-500-1000 V
  • Accuracy 45 Hz – 66 Hz 0.8% + 3
  • Range (autoranging) 20 Ω / 200 Ω / 2000 Ω
  • Accuracy of tTest voltage (at rated test current) +10%, -0%
  • Insulation resistance range 20 MΩ /50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ
  • Test current 1 mA at 50 kΩ 1 mA at 100 kΩ 1 mA at 250 kΩ 1 mA at 500 kΩ 1 mA at 1 MΩ
  • Computation Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
  • RCD Type AC G, S
  • Multiplier x ½, x 1 x 5
  • Specified trip current ranges (EN 61008-1) 50% to 100% for Type AC 35% to 140% for Type A (>10 mA) 35% to 200% for Type A (≤10 mA) 50% to 200% for Type B 5% for Type B
  • Weight (incl. batteries) 1.3 kg
  • Battery size, quantity Type AA, 6 ea.
  • Model 1663 A, AC, G, S
  • Current settings¹ 10-30-100-300-500-1000 mA – VAR 10-30-100 mA
  • Dwell time Type G: 300 ms/step Type S: 500 ms/step