| Specifications of the Thermometer |
| Temperature range | -30°C to 650°C (-22°F to 1202°F) |
| Accuracy | - ±1.0°C or ±1.0% of reading, whichever is greater
- -10°C to 0°C: ±2.0
- -30°C to -10°C: ±3.0
|
| Response time (95%) | < 300 ms (95% of reading) |
| Optical resolution | 12:1 (calculated at 90% energy) |
| Display resolution | 0.1°C (0.2°F) |
| Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater |
| Power | AA battery |
| Battery life | 8 hours with laser and backlight on |
| Physical Specifications |
| Weight | 255 g (8.99 oz) |
| Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) |
| Operating temperature | 0°C to 50°C (32°F to 122°F) |
| Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) |
| Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) |
| Operating altitude | 2000 meters above mean sea level |
| Storage altitude | 12,000 meters above mean sea level |
| IP rating | IP 54 per IEC 60529 |
| Drop test | 3 meters |
| Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
| EMC | EN 61326-1:2006 EN 61326-2:2006 |
| Standards and agency approval | Compliance |
| Laser safety |
| Specifications of Clamp Meter |
| Range | 400.0 A |
| Accuracy | - 2% ±5 digits (45 Hz to 65 Hz)
- 2.5% ±5 digits (65 Hz to 400 Hz)
|
| Range | 600.0 V |
| Accuracy | 1.5% ±5 digits |
| Range | 600.0 V |
| Accuracy | 1.0% ±5 digits |
| Range | 400.0 Ω/ 4000 Ω |
| Accuracy | 1.0% ±5 digits |
| Continuity | ≤ 70 Ω |
| AC response | True-rms |
| Data hold | Yes |
| H x W x D (mm) | 207 x 75 x 34 |
| Max wire diameter | 30 mm (600 MCM) |
| Weight | 265 g |
| Category rating | - CAT III 600 V
- CAT IV 300 V
|
| Specifications of Fluke 1AC-II VoltAlert |
| Operating principle | Senses the steady state electrostatic field produced by ac voltage through the insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicate the presence of voltage. |
| Voltage sensing ranges | Nominally, 90 VAC to 1000 VAC or 200 VAC to 1000 VAC, depending on model, 45 Hz to 405 Hz; also, a 20 V to 90 V control circuit model |
| Light source | One high-intensity red LED |
| Agency approvals | CSA, CE, C-Tick |
| Safety rating | 1000 V, CAT IV |
| IP rating | IP 40 |
| Operating temperature | -10°C to 50°C |
| Operating humidity ranges | - 0% to 95% (0°C to 30°C)
- 0% to 75% (30°C to 40°C)
- 0% to 45% (40°C to 55°C)
|
| Operating altitude | 3000 meters |
| Batteries | 2 AAA alkaline batteries included |