9143-E-156 Includes Only:
- Field Metrology Well
- Report of Calibration and Calibration Label
- E Insert
- Insert Removal Tool
- Serial Cable
- Power Cord
- Software
- Technical Manual on CD
- Users Manual
Whether you need to calibrate 4 to 20 mA transmitters or a simple thermostatic switch, a Field Metrology Well is the right tool for the job. With three models covering the range of -13 to 1220°F (-25 to 660°C), this metrology well calibrates a wide range of sensor types. The optional process version provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4 to 20 mA transmitters which includes the 24 V loop supply to power the transmitter.
Each process version accepts an ITS-90 reference PRT. The built-in readout accuracy ranges from +/-0.01°C to +/-0.07°C depending on the measured temperature. Reference PRTs for Field Metrology Wells contain individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably. The second channel is user-selectable for 2-, 3-, or 4-wire RTDs, thermocouples, or 4 to 20 mA transmitters. For comparison calibration, don't hassle with carrying multiple instruments to the field. Field Metrology Wells do it all as a single instrument.
Traditionally, calibrations of temperature transmitters have been performed on the measurement electronics, while the sensor remained uncalibrated. Studies have shown, however, that typically 75% of the error in the transmitter system (transmitter electronics and temperature sensor) is in the sensing element. Thus, it becomes important to calibrate the whole loop-both electronics and sensor.
The process option makes transmitter loop calibrations easy. The transmitter sensor is placed in the well with the reference PRT and the transmitter electronics are connected to the front panel of the instrument. With 24 V loop power, you are able to power and measure the transmitter current while sourcing and measuring temperature in the Field Metrology Well. This allows for the measurement of as-found and as-left data in one self-contained calibration tool.
Allows for two types of automated thermostatic switch test procedures-auto or manual setup. Auto setup requires the entry of only the nominal switch temperature. With this entry, it will run a 3-cycle calibration procedure and provide final results for the dead band temperature via the display. If you need to customize the ramp rate or run additional cycles, the manual setup allows you to program and run the procedure exactly how you would like. Both methods are fast and easy.
Features:
- Lightweight, portable, and fast
- Cool to -13°F (-25°C) in 15 minutes and heat to 1220°F (660°C) in 15 minutes
- Built-in two-channel readout for PRT, RTD, thermocouple, 4 to 20 mA current
- True reference thermometry with accuracy to +/-0.01°C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading