| Power Source | 120 V AC, 60 Hz |
| Rated Output | 120W |
| Power Consumption | 170 W (rated output), 46 W (based on UL62368), 200 mA or less (when power switch is OFF) |
| Frequency Response | 50 Hz to 20 kHz +/-3 dB (1/8 rated output) |
| Total Harmonic Distortion | 1 % or less at 1 kHz, rated power (20 kHz LPF (AUX-0025)) |
| Tone Control | Bass: +/-10 dB at 100 Hz, Treble: +/-10 dB at 10 kHz |
| Signal to Noise Ration | 88 dB or more (Master volume: min) 76 dB or more (Master volume: max) 55 dB or more (INPUT 1 to 6) (A-weighted) |
| Control Input | 4 channels, no-voltage make contact input, open voltage: 35 V DC or less, Short-circuit current: 10 mA or less, removable terminal block (3.81 mm, 4 pins) |
| REMOTE VOLUME: No-voltage make contact input, open voltage: 35 V DC or less, Short circuit current: 10 mA or less, removable terminal block (3.81 mm, 4 pins) |
| Control Output | POWER REMOTE: Open collector output, withstand voltage: 30 V DC or less, control current: 25 mA or less, removable terminal block (3.50 mm, 4 pins) |
| EMERGENCY OUT: Open collector output, withstand voltage: 30 V DC or less, control current: 25 mA or less, removable terminal block (3.50 mm, 4 pins) |
| Indicators | LED level meter, Power indicator, Network connection confirmation indicator, Priority broadcast indicator, Emergency broadcast indicator, Thermal protection indicator, Over-current protection indicator, CPU running indicator, Error indi-cator |
| Operating Temperature | -10 to +40 °C (14 to 104 °F) |
| Operating Humidity | 85 % RH or less (no condensation) |
| Finish | Panel: ABS resign, black Case: Surface-treated steel plate, black, paint | | |
| Dimensions | 420 (w) x 96.1 (h) x 313.1 (d) mm or 16,54" x 3.78" x 12.33" |
| Weight | 5.2 kg or 11.46 lb |
| Options | Input transformer: IT-450, Perforated panel: PF-013B |