SPX Power Team, 9628, Post-Tensioning Valve for 10,000 PSI Single-Acting/Power Wedge Seater
Features:
- Applications: Single strand, double-acting stressing jacks with Power Wedge seater.
- Actuation: Lever-operated, detent-positioned.
- Operation:
- With valve in center position, pump is started.
- Cable is inserted into stressing tool, valve is placed in "A" position. "Pull" portion of stressing tool is pressurized to specified level for proper cable tensioning ("A" port is checked internally, can only be released by building pressure in "B" position).
- Valve is placed in "B" position, which is pressure controlled and will not exceed 6,400 psi. "Return" portion of stressing tool is pressurized and will release "A" port when pressure reaches approximately one-half the "A" port pressure. "A" port remains open as long as this pressure differential is maintained.
- Pump is stopped, valve is placed in "A" position, releasing "B" port pressure.
- Used on these pumps: PA17*, PA46*, PA55, PE17*, PE21*, PE30, PE46*,PE55, PE60, PE120, PE400, PG30*, PG55, PG120, PG400, PQ60 andPQ120 series.