Features:
- Insulation Resistance Measurement: The instrument is capable of measuring insulation resistance from 10 K - 999 MΩ
- Hands-free continuity testing: Continuity testing (0-10 with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated.
- Automatic discharge for capacitive circuits after test measurement: Capacitive devices under test, such as cables and windings, that get charged during the test, are discharged by the tester.
- Live circuit detection: Displays the presence of voltages >25V irrespective of the function selected.
- Pre-selectable measurement time for Insulation Resistance Measurement: In the normal course, the insulation test terminates and the measured insulation resistance value remains on display for 2 sec after the test key is released. With the Pre-selectable measurement time feature, the insulation test continues and the measured value remains on the display for the pre-determined time. Pre-selectable time: 10 sec - 5 min.
- Pre-selectable limit checks for MΩ: An acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value.
- Lead resistance null facility: The instrument provides a facility to compensate for the resistance of the leads for accurate measurement of low resistance.
- Storage of MIN/MAX values: In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored.
- Storage Memory for the last 50 readings: The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement.
- Blown fuse indication: The display FUSE points to a blown fuse.
- Low battery indication: Automatic display of the Symbol "- " when battery cells are exhausted.
- Stop Watch: This function allows you to measure elapsed time up to 1 hour
- Auto-power-off function: The instrument turns off automatically if any of the keys or the selector switch has not been activated for about 10 minutes in the insulation range and 5 minutes in other ranges or can be switched to continuous operation.
- Protective holster for rough duty: A holster of soft rubber with a tilt stand protects the meter against damage in the case of shock and drop.
Analog-Digital Insulation and Continuity Tester are suitable for following Measurements of the insulation resistance on electrically dead equipment and systems with test voltages up to 1000V For testing motors, transformers, generators, and switchgear. For testing of house hold appliances. Measurement of the insulation resistance of cables. Very useful for onsite maintenance and service departments.
For more information, please see
Data Sheet