Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Sifam Tinsley
Alpha 30 Multifunction Meter

Sifam Tinsley AP30-23GURZZ000000 Alpha 30 Multifunction Meter

Part #:
AP30-23GURZZ000000
Model #:
Alpha 30
Condition:
Brand New

Choose Input Frequency (Hz)

Choose Modbus Output

$332.70 /Each
Free shipping
3-4 Weeks Factory Lead Time
Check availability
$332.70 /Each

Notification

Item is non-returnable unless defective.
Please review our Return Policy.
Manufacturer warranty

Description

$332.70 /Each
Free shipping
3-4 Weeks Factory Lead Time
Check availability

Technical details

Main features
  • Input Frequency (Hz) 50 - 60
  • Power Cos phi/sin phi = 1 for Active/ Reactive Power & Energy. 10 - 100 % of the Nominal Current 0 - 100% of Nominal Voltage.
  • Voltage 2 x rated value for 1 second, repeated 10 times at 10-second intervals, 5 - 120% of rated value
  • Frequency 40 - 70Hz / 400Hz
  • Modbus Output Used
  • Voltage Range 50 - 100% of Nominal Value. 60 - 100% of Nominal Value for THD.
  • Current 20x for 1 second, repeated 5 times at 5 min, 5 - 120% of rated value
  • Relative Humidity 0 - 95% non-condensing
  • Operating Temperature -20 to +70°C
  • Storage Temperature -30 to +80°C
  • Vibration 10 - 55 Hz, 0.15mm amplitude
  • Shock 15g in 3 planes
  • Temperature Coefficient 0.025%/°C for Voltage (50. 120% of rated value) 0.05%/°C for Current (10. 120% of rated value)
  • Reference Temperature 23°C +/- 2°C
  • Input Waveform Sinusoidal (distortion factor 0.005)
  • Input Frequency 50 or 60 Hz
  • Auxiliary Supply Voltage Rated Value +1 %
  • Auxiliary Supply Frequency Rated Value +1 %
  • Nominal Input Voltage (AC RMS) Phase -Neutral: 63.5 / 133 / 239.6 / 254 VL-N Line-Line: 110 / 230 / 415 / 440 VL-L
  • Max Continuous Input Voltage 120% of the rated value
  • Nominal Input Voltage Burden < 0.2 VA approx. per phase
  • Nominal Input Current 5A AC RMS.
  • System CT Secondary Values 1A & 5A is programmable on-site.
  • System CT Primary Values From 1A up to 9999A (for 1 or 5 Amp )
  • Max Continuous Input Current 120% of the rated value
  • Nominal Input Current Burden < 0.6 VA approx. per phase
  • Current Range 10 - 100 % of Nominal Value. 20 - 100% of Nominal Value for THD.
  • Warm-Up Time Minimum 3 minute
  • Power Factor 0.5 Lag - 1. 0.8 Head
  • Power Factor / Phase Angle 40 - 100% of the Nominal Current 50 - 100% of Nominal Voltage
  • EMC IEC 61326
  • Safety IEC 61010-1-2001, Permanently connected use
  • IP for Water & Dust IEC60529
  • Immunity IEC 61000-4-3. 10V/m min
  • Pollution Degree 2
  • Installation Category III
  • High Voltage Test 2.2 kV AC, 50Hz for 1 minute between all electrical circuits
  • System FT Primary Values 100VLL to 692kVLL programmable on-site.
  • AC Auxiliary Supply Frequency Range 45 to 66 Hz
  • Auxiliary Supply Burden < 4 VA approx OR < 5VA approx with 4-20mA analog output
  • Response Time to Step Input 1 sec approx.
  • Default Pulse Rate CT secondary = 1A Max pulse rate 3600 pulses/Ah
  • Divisor CT secondary = 5A Max pulse rate 720 pulses/Ah
  • Pulse Duration 60 ms, 100 ms or 200 ms
  • AC-DC Auxiliary Supply 100V - 250 VAC DC +/ - 10%