Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Sifam Tinsley
Alpha 30 Multifunction Meter

Sifam Tinsley AP30-238URZZ000000 Alpha 30 Multifunction Meter

Part #:
AP30-238URZZ000000
Model #:
Alpha 30
Condition:
Brand New
$332.70 /Each
Free shipping
3-4 Weeks Factory Lead Time
Check availability
$332.70 /Each

Notification

Item is non-returnable unless defective.
Please review our Return Policy.
Manufacturer warranty

Description

$332.70 /Each
Free shipping
3-4 Weeks Factory Lead Time
Check availability

Technical details

Main features
  • Power Cos phi/sin phi = 1 for Active/ Reactive Power & Energy. 10 - 100 % of the Nominal Current 0 - 100% of Nominal Voltage.
  • Voltage 2 x rated value for 1 second, repeated 10 times at 10-second intervals, 5 - 120% of rated value
  • Frequency 40 - 70Hz / 400Hz
  • Outputs Outputs not Used
  • Voltage Range 50 - 100% of Nominal Value. 60 - 100% of Nominal Value for THD.
  • Model Type Alpha 30
  • Current 20x for 1 second, repeated 5 times at 5 min, 5 - 120% of rated value
  • Relative Humidity 0 - 95% non-condensing
  • Operating Temperature -20 to +70°C
  • Storage Temperature -30 to +80°C
  • Vibration 10 - 55 Hz, 0.15mm amplitude
  • Shock 15g in 3 planes
  • Temperature Coefficient 0.025%/°C for Voltage (50. 120% of rated value) 0.05%/°C for Current (10. 120% of rated value)
  • Reference Temperature 23°C +/- 2°C
  • Input Waveform Sinusoidal (distortion factor 0.005)
  • Input Frequency 50 or 60 Hz
  • Auxiliary Supply Voltage Rated Value +1 %
  • Auxiliary Supply Frequency Rated Value +1 %
  • Nominal Input Voltage (AC RMS) Phase -Neutral: 63.5 / 133 / 239.6 / 254 VL-N Line-Line: 110 / 230 / 415 / 440 VL-L
  • Max Continuous Input Voltage 120% of the rated value
  • Nominal Input Voltage Burden < 0.2 VA approx. per phase
  • Nominal Input Current 5A AC RMS.
  • System CT Secondary Values 1A & 5A is programmable on-site.
  • System CT Primary Values From 1A up to 9999A (for 1 or 5 Amp )
  • Max Continuous Input Current 120% of the rated value
  • Nominal Input Current Burden < 0.6 VA approx. per phase
  • Current Range 10 - 100 % of Nominal Value. 20 - 100% of Nominal Value for THD.
  • Warm-Up Time Minimum 3 minute
  • Power Factor 0.5 Lag - 1. 0.8 Head
  • Power Factor / Phase Angle 40 - 100% of the Nominal Current 50 - 100% of Nominal Voltage
  • EMC IEC 61326
  • Safety IEC 61010-1-2001, Permanently connected use
  • IP for Water & Dust IEC60529
  • Immunity IEC 61000-4-3. 10V/m min
  • Pollution Degree 2
  • Installation Category III
  • High Voltage Test 2.2 kV AC, 50Hz for 1 minute between all electrical circuits
  • System FT Primary Values 100VLL to 692kVLL programmable on-site.
  • AC Auxiliary Supply Frequency Range 45 to 66 Hz
  • Auxiliary Supply Burden < 4 VA approx OR < 5VA approx with 4-20mA analog output
  • Response Time to Step Input 1 sec approx.
  • Default Pulse Rate CT secondary = 1A Max pulse rate 3600 pulses/Ah
  • Divisor CT secondary = 5A Max pulse rate 720 pulses/Ah
  • Pulse Duration 60 ms, 100 ms or 200 ms
  • AC-DC Auxiliary Supply 100V - 250 VAC DC +/ - 10%