Sifam Tinsley, AP20-311EALR000000, Alpha 20 Multifunction Meter with Limit Switch, 3 Phase, 100-500V, 1/5A Input, 40-300V AC-DC Aux Supply, RS 485
Features:
- On-site programmable PT/CT ratios: It is possible to program the primary of the potential external Transformer (PT), and the primary of the external Current Transformer (CT) on site via front panel keys by entering into Programming mode.
- User-selectable CT Secondary 5A / 1A: The secondary external Current Transformer (CT) can be programmed on-site to either 5A or 1A using front panel keys.
- User-selectable PT Secondary: The secondary of the Potential external Transformer (PT) can be programmed on-site from 100VLL to 500VLL using front panel keys.
- Four function keys: Using the four function key, it is possible to go desired parameter screen instantly.
- Low back depth: The instrument has a very low back depth (behind the panel) of less than 60mm.
- Demand Measurement: Measures & Displays Current Demand, kVA Demand, kW Import Demand, kW Export Demand.
- 3 line 4 digits LED display: Simultaneous display of 3 Parameters.
- RPM Measurement: The instrument display Rotation per minute for generator applications. A number of poles can be set on-site depending on application requirements.
- Energy Count Storage: In case of power failure, the instrument memorizes the last energy count. Every 1 min, the instrument updates the energy counter in the non-volatile memory
- User selectable 3 phase 3Wire 4Wire or Single phase Network: User can program on-site the network connection as either 3 Phase 3 Wire/4 Wire or single phase network using front panel keys.
- Onsite selection of Auto scroll / Fixed Screen: Use can set the display in auto scrolling mode or fixed screen mode rising front panel keys
- Limit switch (Relay): The instrument will trip the relay if the programmed parameter exceeds the programmed Trip Limits.
- Enclosure Protection for dust and water: Conforms to IP 50 (for front face) & IP 20 (for back) & as per IEC60529.
- Storage of parameters possible: The instrument stores minimum and maximum values for System Voltage, System Current, Run Hour, ON Hour & number of Interrupts. Every 60 sec stored values are updated.
- True RMS measurement: The instrument measures distorted waveform up to the 15th Harmonic.
- Energy Measurement (Import & Export): Active Energy (kWh), Reactive Energy (kVArh), Apparent Energy (kVAh).
Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. It measures electrical parameters like AC Voltage, AC Current, Frequency, Active, Reactive, Apparent Power, Import Export Energy & many more.
For more information, please see
Data Sheet