| Output: Inverter mode |
| Continuous Active Output Power | 1500W (Power Factor = 1) |
| Maximum Surge Power | 3000W (<4 milliSec; Power Factor = 1) |
| Nominal Output Voltage | 115 VAC, +10% / -5% |
| Output Frequency | 60 Hz ± 5% |
| Efficiency | 87% (at 100% Load) |
| Inverter on/off Control | By front panel Switch |
| Output: Grid Pass Through |
| Nominal Voltage, Frequency of Grid | 120 VAC, 60 Hz |
| Pass Through |
| Maximum Power | 1500W (Power Factor = 1; Battery fully charged) |
| Input: Battery |
| Battery System Voltage | 12V (10.5V to 15.5V ± 0.5V) |
| DC current draw from battery at Output Power | 150ADC at battery Voltage of 12.5 VDC |
| DC no Load current draw in inverter mode | 0.65A to 0.85A |
| Input: Grid |
| Nominal Voltage, Frequency | 120 VAC, 60 Hz |
| Maximum AC Input current | 15A (Protected by 15A breaker supplying Grid Input) |
| Transfer Relay K1 |
| Current rating of transfer relay | 30A |
| Transfer time from grid to inverter | 2 to 3 Seconds |
| Transfer time from inverter to grid | Up to 1 Second |
| Ground Switching Relay K2 |
| Current Rating | 12A |
| Battery charger |
| ChargingAlgorithm | 2 Stage Charger - Bulk & Float |
| Float Voltage | 13.8V ± 0.3V |
| Bulk charge/max. Charging current | 15A |
| Maximum ac Input current | < 5A at 120 VAC |
| AC Input Power factor | 0.6 |
| Efficiency | 80 ± 5% |
| Voltage & current rating of Fuse | - 5 mm x 20 mm, Fast Acting Glass Tube Fuse 125V / 250V, 5A
- Bussman GMA-5 or equivalent
|
| Charger on/off control | By front panel Switch |
| Pass Through Mode: Load Side |
| Overload / Short Circuit Shutdown | Load >15A: Input Circuit Breaker on the unit will trip |
| Pass Through Mode: Charger Section |
| High AC Input Voltage Shutdown | 143 VAC. Auto reset at 138 VAC (No transfer to Inverter) |
| Low AC Input Voltage Shutdown | < 10 VAC. Auto reset at > 75 VAC (No transfer to Inverter) |
| Ground Fault Shutdown In Charger / Pass Through Mode | GFCI of AC outlet supplying AC Input will trip |
Protections: Inverter Mode
|
| Overload Shutdown | > 1650 ± 10% for up to 7 Sec |
| Low battery Input Voltage Alarm | 10.8 ± 0.3V |
| Low battery Input Voltage Shutdown | 10.5 ± 0.3V ; Auto reset at 11.7 ± 0.3V |
| Battery (Input) Over Voltage Shutdown | > 15.5V ; Auto reset at < 15.5V |
| Cooling - Load Controlled Fan | Inverter Mode: ON at 85W ; Charging Mode: ON at Charging current > 3A ± 1A |
| Inverter Over Temperature Shutdown | Internal hot spot > 88° to 110°. Auto reset when hot spot cools down 10° to 15°C beLow the threshold |
| Ground Fault Shutdown | Leakage > 5.8 mA. Manual reset |
| DC Input reverse polarity | Fuse 240A (8 pcs. 30A Automotive Type at Fuses in parallel) |
| Connections |
| DC Input | Nut & Bolt, M9 |
| AC Input / AC Output | 6 foot cord with NEMA5-15P Plug / 2 x NEMA5-15R Outlets |
| General |
| LED display | Green “Inverter”; Green “Charger”; Red “Fault”; Yellow “Input Fault” |
| Operating Temperature Range (Min. to Max.) | 0°C to 25°C / 32°F to 77°F at 100% Loading; 26°C to 35°C / 78.8°F to 95°F at 80% Loading |
| Operating Humidity | < 80%; Non-condensing |
| Dimensions (W x D x H) | 202 x 345 x 84 mm / 7.95 x 13.58 x 3.30 in |
| Weight | 4.0 kg / 8.82 lb |