Output |
Output Voltage | 120 VAC ± 3% |
Maximum Output Current | 5.1A |
Output Frequency | 60 Hz ± 1% |
Type of Output WaveForm | Pure Sine Wave |
Total Harmonic Distortion | < 3% |
Continuous Output Power (at Power Factor = 1) | 600 Watts |
Surge Output Power | 1000 Watts (< 8 ms) |
Peak Efficiency | >90% |
AC Output Connections | NEMA5-20R GFCI Duplex Receptacle |
Input |
Nominal DC Input Voltage | 48V |
DC Input Voltage Range | 42.0 - 64.0 VDC |
Maximum Input Current | 20A |
DC Input Current at No Load | < 0.3A |
DC Input Connections | Bolt & Nut: 5/16” x 18 TPI |
DC Input Fuses (Internal) | 2 x 10A = 20A (Each 10A, 58V, Blade Type) |
Display |
LED | Power, Overload, Over Temperature |
Protections |
Low DC Input Voltage Alarm | 42.0V ± 0.5V |
Low DC Input Voltage Shutdown | 40.0 ± 0.5 VDC ; Auto-reset: 46.0 ± 0.5 VDC |
High DC Input Voltage Shutdown | 64.0 VDC ; Auto-reset: < 64.0 VDC |
Short Circuit Shutdown | When Output Voltage drops to 80V or Lower for up to 2.5 Sec |
Overload Shutdown | At Overload of 110% to 115% for 2 to 2.5 Sec |
Ground Fault Shutdown | Through GFCI outlets (5 to 6 mA leakage) |
Over Temperature Shutdown | 90°C ± 5°C (Sensed at Transformer T3) ; Auto-reset at 65°C ± 5°C |
Reverse Polarity on DC Input Side | External / internal DC sides fuses will bLow |
Cooling |
Forced Air Cooling | - Temperature Controlled Fan
- Fan ON at 55°C ± 3°C; Fan off at 45°C ± 3°C
|
Compliance |
European Conformity | CE marked |
Safety | Intertek - ETL Listed. Conforms to UL Standard 458 and certified to CSA Std. C22.2 No. 107.1 |
EMI / EMC | FCC Part 15(B), Class B |
Environment |
Operating Temperature Range | - Operating Temperature -20 to 40°C / -4 to 104°F
- Storage Temperature -30 to 70°C / -22 to 158°F
- 90% relative humidity non-condensing
|
Dimensions (W X D X H), Mm | 238 x 276.2 x 82 |
Dimensions (W X D X H), Inches | 9.37 x 10.87 x 3.23 |
Weight |
KG | 2.7 |
LBS | 5.9 |