| Input Range | 180Vac-285Vac |
| Input Frequency | 50Hz/60Hz |
| Output |
| Capacity | 2000VA/1800W |
| Output Voltage | 100V/110V/115V/120V Selectable |
| Output Current-Amps at 60Hz | 16.8 Amp |
| Output Peak Current (<250mS) | 50 Amp |
| Voltage Regulation | ±2% of selected output voltage |
| Output Frequency (Sync To Mains) | 50±0.05Hz or 60±0.06Hz (Auto-Synchronized to Mains) |
| Output Frequency (Not Sync To Mains) | 50/60Hz (selectable from LCD function button) 50±0.01Hz or 60±0.01Hz |
| Crest Factor | 3:1 |
| Voltage Waveform | Sine Wave |
| Output Distortion (Resistive Load) | <2% |
| Output Distortion (Reactive Load) | <3% |
| Non-Linear Peak Current for 30 sec. | 36A |
| Standby Power | 27W |
| Total Harmonic Distortion | <3% (at full resistive load) |
| Output EMI Filter | N/A |
| Output RFI Filter | 30Mhz - 1000Mhz |
| Clamp Level | 200V PEAK |
| Protection |
| Over load Protection | - 100%~129% for 60 seconds delay, then alarm
- Alarm for 60 seconds, then shutdown o/p
- > 130%, alarm for 2 seconds, then shutdown o/p
|
| 4A | - Output protected from short circuit by pulsating type
- Auto-Restart time: 30 seconds
|
| Input |
| Voltage Range | 180V~285Vac |
| Maximum Continuous Load | 1800W |
| Maximum Peak Load | 2400W |
| Input Current | 12 Amp |
| Input Frequency Range | 45Hz ~ 70Hz |
| Phase | Single |
| Noise Filtering | Full-Time EMI/RFI Filtering |
| Input EMI Filter | 150Khz -30Mhz (class A) |
| Input RFI Filter | 30Mhz - 1000Mhz (class A) |
| Over Current Protection | By Re-Settable Over Current Protector |
| Voltage Range | 180 V ~ 285 Vac |
| Power Factor | ≥0.98 |
| Audible Alarm | - Over load alarm
- Short-circuit alarm
- Thermal alarm
|
| Inrush Surge Capacity | <100A, 3mS |
| Voltage Interruption Ride Through | 10mS |
| Efficiency |
| Efficiency | >89% |
| Output Connection from Mains |
| Ground | Input and Output Ground Connected |
| Neutral | - Input and Output Neutral Connected (after EMC inductor )
- Isolation Transformer is not required
|
| Indicators |
| LCD Control Panel | - Displays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level
- Selectable Output Voltage and Output Frequency
|
| LED | N/A |
| Output Compatibility |
| Output Compatibility with UPS | Yes |
| Environmental and Safety |
| Operating Temp. | Up to 1500 meters: 0°C to 40°C (32°F to 104°F) |
| Transit/storage Temp. | -15°C to 55°C (5°F to 131°F) |
| Relative Humidity | 5 - 95% Non-Condensing |
| Operating Altitude | 0 ~ 3000 Meters |
| Moisture Sensitivity | Internal Fan |
| Audible Noise | ≤45 dBA (at 1 meter from surface of unit) |
| Cooling |
| Type Ventilation | Natural Ventilation |
| External Cooling Fan Control | Forced air cooling by internal fan |
| Physical |
| Dimensions WxDxH | 51 x 20 x 18 cm / 20.08 x 7.87 x 7.08 in |
| Weight Net/Gross | 8.0 kg / 17.64 lbs |
| Shipping Dimension | 26.00 x 16.00 x 16.00 in / 66.04 x 40.64 x 40.64 cm |
| Shipping Weight | 28.00 lbs / 12.70 kgs |
| Others |
| Standard Accessories | Input Power Cords: |
| Wall Mountable | No |
| Quality Control Standard | ISO9001 |
| Approvals and Safety Markings | CE |