Ambient Conditions | 23°C / 73.4°F ± 5°C / 41°F, < 75% RH |
Current Measurement AC | - Measuring range: 60 A / 600 A / 1000 A
- Resolution: 0.01 A / 0.1 A / 1 A
- Accuracy: ± 2% + 8 Dgt / ± 2% + 8 Dgt / ± 2% + 8 Dgt
|
Maximum Input Current | 1000 A AC |
Frequency Range | 40 - 400 Hz |
Inrush Current AC | - Measuring range: 60 A / 600 A / 1000 A
- Resolution: 0.01 A / 0.1 A / 1 A
- Accuracy: For reference Only / ± 5% + 60 Dgt / ± 5% + 60 Dgt
|
Integral Time | 100 ms |
Measuring Range | 20 - 1000 A |
Frequency Range | 40 - 400 Hz |
Voltage Measurement DC | - Measuring range: 6V / 60V / 600V / 1000V
- Resolution: 0.001V / 0.01V / 0.1V / 1V
- Accuracy: ± 0.5% + 5 Dgt / ± 0.5% + 5 Dgt / ± 0.5% + 5 Dgt / ± 0.8% + 4 Dgt
|
Input Impedance | 10 MΩ |
Maximum Input Voltage | 750V AC (rms value) or 1000V DC |
Voltage Measurement AC | - Measuring range: 6V / 60V / 600V / 1000V
- Resolution: 0.001V / 0.01V / 0.1V / 1V
- Accuracy: ± 0.6% + 4 Dgt / ± 0.6% + 4 Dgt / ± 0.6% + 4 Dgt / ± 0.8% + 4 Dgt
|
Input Impedance | 10 MΩ |
Maximum Input Voltage | 750V AC (rms value) or 1000V DC |
Frequency Range | 40 - 400 Hz |
Frequency Measurement with the Current Measuring Function | - Measuring range: 99.99 Hz / 999.9 Hz
- Resolution: 0.01 Hz / 0.1 Hz
- Accuracy: ± 1.5% + 5 Dgt / ± 1.5% + 5 Dgt
|
Measuring Range | 10 - 1 kHz |
Measuring Range of the Input Signal | > 20 AAC (rms value) |
Maximum Input Current | 1000 AAC (rms value) |
Frequency Measurement with the Voltage Measurement Function | - Measuring range: 99.99 Hz / 999.9 Hz / 9, 999 kHz
- Resolution: 0.01 Hz / 0.1 Hz / 0.001 kHz
- Accuracy: ± 1.5% + 5 Dgt / ± 1.5% + 5 Dgt / ± 1.5% + 5 Dgt
|
Measuring Range | 10 - 10 kHz |
Measuring Range of the Input Signal | 1V AC (rms value) |
Maximum Input Current | 1000 V AC (rms value) |
Frequency Measurement | Measuring range: 9, 999 Hz / 99.99 Hz / 9, 999 kHz / 999.9 Hz / 99.99 kHz / 999.9 kHz / 9, 999 MHz Resolution: 0.001 Hz / 0.01 Hz / 0.1 Hz / 0.001 kHz / 0.01 kHz / 0.1 kHz / 0.001 MHz Accuracy: ± 0.3% + 5 Dgt / ± 0.3% + 5 Dgt / ± 0.3% + 5 Dgt / ± 0.3% + 5 Dgt / ± 0.3% + 5 Dgt / ± 0.3% + 5 Dgt / ± 0.3% + 5 Dgt |
Overvoltage Protection | 1000V DC or 750V AC (rms value) |
Range of Voltage Input | > 2V |
Duty Cycle | - Measuring range: 0.1 - 99.9%
- Resolution: 0.10%
- Accuracy: ± 0.3% + 5 Dgt
|
Frequency Range | 10 - 10 kHz |
Voltage Range | 2 - 250V AC |
Duty Cycle with the Current Measurement Function | - Frequency range: 10 - 1 kHz
- Input current: 20 - 1000 AAC (rms value)
|
Duty Cycle with the Voltage Measurement Function | - Frequency range: 10 - 1 kHz
- Input current: 1 - 750V AC (rms value)
- Input impedance: 1MΩ
|
Resistivity | - Measuring range: 600 Ω / 6 kΩ / 60 kΩ / 600 kΩ / 6 MΩ / 60 MΩ
- Resolution: 0.1 Ω / 0.001 kΩ / 0.01 kΩ / 0.1 kΩ / 0.001 MΩ / 0.1 MΩ
- Accuracy: ± 0.8% + 3 Dgt / ± 0.8% + 3 Dgt / ± 0.8% + 3 Dgt / ± 0.8% + 3 Dgt / ± 2% + 5 Dgt / ± 2% + 5 Dgt
|
Measuring Voltage | approx. 0.78V |
Overvoltage Protection | 750V DC, 1000V AC (rms value) |
Continuity Test | - Measuring range: 600 Ω
- Resolution: 0.1 Ω
|
Acoustic Signal | at < 50 Ω |
Test Voltage | 1.48V |
Overvoltage Protection | 750V DC, 1000V AC (rms value) |
Capacitance Measurement | - Measuring range: 9.999 nF / 99.99 n.f. / 999.9 nF / 9.999 µF / 99.99 µF / 999.9 µF / 9, 999mF / 99.99 mF
- Resolution: 0.001 nF / 0.01 nF / 0.1 nF / 0.001 µF / 0.01 µF / 0.1 µF / 0.001 mF / 0.01 mF
- Accuracy: ± 3% + 5 Dgt / ± 3% + 5 Dgt / ± 3% + 5 Dgt / ± 3% + 5 Dgt / ± 3% + 5 Dgt / ± 3% + 5 Dgt / ± 3% + 5 Dgt / ± 3% + 5 Dgt
|
Overvoltage Protection | 750V DC, 1000V AC (rms value) |
Diode Measurement | - Measuring range: 3V
- Resolution: 0.001V
|
DC Anode Side | approx. 1-mA |
DC Cathode Side | approx. 3.2V |
Overvoltage Protection | 750V DC, 1000V AC (rms value) |
Single Phase Power Measurement | - Measuring range: 3 W / VA / Var - 100 W / VA / Var - 4000 W / VA / Var - 10 kW / VA / var - 100 kW / VA / var - 750 kW / VA / var
- Resolution: 0.01 W / VA / Var - 0.1 W / VA / Var - 1 W / VA / Var - 0.01 kW / VA / Var - 0.1 kW / VA / Var - 1 kW / VA / Var
- Accuracy: ± 3% + 5 Dgt - ± 3% + 5 Dgt - ± 3% + 5 Dgt - ± 3% + 5 Dgt - ± 3% + 5 Dgt - ± 3% + 5 Dgt
|
Smallest Measuring Current | 1-mA |
Smallest Measuring Voltage | 1V |
Power Factor Capacitive / Inductive | - Measuring range: 0.1 - 1
- Resolution: 0.001
- Accuracy: ± 5% + 5 Dgt
|
Smallest Measuring Current | 1-mA |
Smallest Measuring Voltage | 1V |
Harmonics Measurement | - Measuring range: 1 - 2 - 6 / 7 - 8 / 9 - 10 / 11 - 15 / 16 - 20
- Accuracy: ± 3% + 10 Dgt / ± 3.5% + 10 Dgt / ± 4.5% + 10 Dgt / ± 5% + 10 Dgt / ± 7% + 10 Dgt / ± 10% + 10 Dgt
|
Smallest Measuring Current | 1-mA |
Smallest Measuring Voltage | 1V |
General Specifications |
Measuring Range | Automatically and manually adjustable |
Maximum Voltage Range | 1000V DC or 750V AC |
Maximum Working Height | 2000 m / 6561 ft |
Display | LCD |
Maximum Display | 5999 Dgt. |
Overrange | " OIL" |
Measuring Range Underflow | " -OL" |
Measuring Rate | 3 Hz |
Automatic Shutdown | After 30 minutes |
Power Supply | 9V block battery |
Battery Indicator | Icon if the battery voltage is too low |
Temperature Coefficient | 0.1 x accuracy x °C / °F |
Operating Conditions | 0 - 40°C, 32 - 104°F |
Storage Conditions | -10 - 60°C, 14 - 140°F |
Dimensions | 238 x 92 x 50 mm / 9.4 x 3.6 x 2 in |
Weight | About 420 g / < 1 lb (with batteries) |