Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Inor
R530X Universal HART-Compatible 2-Wire Transmitter

Inor 70R530F010 R530X Universal HART-Compatible 2-Wire Transmitter

Brand: Inor
Part #:
70R530F010
Model #:
R530X
Condition:
Brand New

Choose Intrinsic Safety

$440.00 /Each
Typically In Stock
Check availability
$440.00 /Each
Manufacturer warranty

Description

$440.00 /Each
Typically In Stock
Check availability

Technical details

Main features
  • Configuration ConSoft, INOR Connect or EDD, DTM / FDT-system
  • Input RTD, TC, mV, ohm
  • Power Supply 8.5 to 30 VDC
  • Output 4-20 mA, HART protocol
  • Intrinsic Safety ATEX / IECEx
  • Type Rail-mounted
  • Vibration IEC 60068-2-6, 8g
  • Ambient Temperature -40...+85 °C / -40...+185 °F
  • EMC EN 61326-1 and EN 61326-2-3
  • Humidity 0...98% RH (non-condensing)
  • Sensor connection 2-, 3-, 4-wire connection
  • Wireless Connectivity NFC and Bluetooth
  • Input Thermocouple Type B, C, D, E, J, K, N, R, S, T
  • Input RTD Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Galvanic isolation 1500 VAC
  • Type of transmitter Digital
  • Sensor error NAMUR NE43
  • Adjustments - Zero point Any value within range limits
  • Typical accuracy Max. ±0.08K or ±0.08% of span
  • Adjustable filtering level 0.17 to 90 s (standard 0.9 s) (3-wire RTD)
  • Measuring channels 1 Channel
  • Accuracy over time Max. drift ±0,02% of span/year
  • Runtime counter Hour counter for elapsed operational time
  • Simulated output Fixed current output during a maximum time of 15 min
  • HART compliance Fully compliant with the HART 7 protocol as well as the previous HART 6 and 5
  • Adjustments - Min. span 10°C / 18°F or according to the sensor
  • Error compensation Sensor and system error correction