| Product Characteristics |
| Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
| Communication Interface | IO-Link |
| Process Connection | Clamp DN25 - DN40 (1 - 1,5") DIN 32676 (ISO 2852) |
| Installation length EL [mm] | 50 |
| System | Gold-plated contacts |
| Measuring Element | 1 x Pt 1000 |
| Reference element | 1 x NTC |
| Media | Liquids and gases |
| Pressure Rating [bar] | 160 |
| Electrical Data |
| Operating Voltage [V] | 18 - 32 DC; (cULus - Class 2 source required) |
| Current Consumption [mA] | 10; (24 V) |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | 6 |
| Integrated Watchdog | Yes |
| Inputs / Outputs |
| Number of Inputs and Outputs | - Number of Digital Outputs: 1
- Number of Analog Outputs: 1
|
| Outputs |
| Total Number of Outputs | 2 |
| Output Signal | Analog signal; IO-Link; calibration check status |
| Electrical Design | PNP/NPN |
| Number of Digital Outputs | 1 |
| Output Function | Normally closed; (diagnostic signal) |
| Maximum Voltage Drop Switching Output DC [V] | 2 |
| Permanent Current Rating of Switching Output DC [mA] | 100 |
| Diagnostic output | Calibration check status and error diagnostics |
| Number of Analog Outputs | 1 |
| Analog Current Output [mA] | 4 - 20 |
| Maximum Load [Ω ] | (Ub - 15 V) x 50 |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Yes (non-latching) |
| Overload Protection | Yes |
| Measuring/Setting Range |
| Note on measuring range |
| Factory Setting | -10 - 150 ° C / 14 - 302 ° F |
| Calibration check limit [K] | 0.5 - 3 |
| In steps of [K] | 0.05 |
| Resolution |
| Resolution of Analog Output [K] | 0.05 |
| Accuracy / Deviations |
| Precision analog output [K] | ± 0,2 |
| Precision IO-Link [K] | ± 0,2 |
| Temperature coefficient analog output [% of the span / 10 K] | < ± 0,02; (In case of deviation from the reference condition 25 ± 5 ° C) |
| Temperature coefficient IO-Link [% of the span / 10 K] | < ± 0,01; (In case of deviation from the reference condition 25 ± 5 ° C) |
| Reaction Times |
| Dynamic Response T05 / T09 [s] | 1,5 / 4 |
| Software / Programming |
| Parameter Setting | Display Unit; scaling of the analog output; calibration check limit; switching logic diagnostic output; simulation mode |
| Interfaces |
| Communication Interface | IO-Link |
| Transmission Type | COM2 (38,4 kBaud) |
| IO-Link Revision | 1.1 |
| SDCI Standard | IEC 61131-9 CDV |
| Profiles | Digital Measuring Sensor, Common Profile, Blob Transfer |
| SIO Mode | Yes |
| Required Master Port Class | A |
| Process Data Analog | 1 |
| Process Data Binary | 1 |
| Minimum Process Cycle Time [ms] | 4.4 |
| IO-Link Resolution Temperature [K] | 0.01 |
| Operating Conditions |
| Ambient Temperature [° C] | -25 - 70 |
| Storage Temperature [° C] | -40 - 100 |
| Protection | IP 68; IP 69K |
| MTTF [Years] | 329 |
| Mechanical Data |
| Weight [g] | 352.3 |
| Dimensions [mm] | Ø 50 / L = 114.8 |
| Material | Stainless steel (1.4404 / 316L); PEI; FKM; PFA |
| Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); PEEK |
| Process Connection | Clamp DN25 - DN40 (1 - 1,5") DIN 32676 (ISO 2852) |
| Surface characteristics Ra/Rz of the wetted parts | Ra: <0.8 |
| Probe Diameter [mm] | 6 |
| Installation length EL [mm] | 50 |
| Electrical Connection |
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |