| Product Characteristics |
| Number of Inputs and Outputs | Number of Digital Outputs: 2 |
| Process Connection | Threaded connection G 1 flat seal |
| System | Gold-plated contacts |
| Installation | Connection to pipe by means of an adapter |
| Media | Water; glycol solutions; Coolants; oils |
| Medium Temperature [° C] | -10 - 80 |
| Electrical Data |
| Operating Voltage [V] | 19 - 30 DC; (to SELV/PELV) |
| Current Consumption [mA] | 100 |
| Minimum Insulation Resistance [MΩ ] | 100; (500 V DC) |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | 10 |
| Inputs / Outputs |
| Number of Inputs and Outputs | Number of Digital Outputs: 2 |
| Outputs |
| Total Number of Outputs | 2 |
| Output Signal | Switching signal |
| Electrical Design | PNP |
| Number of Digital Outputs | 2 |
| Output Function | Normally open / closed; (configurable) |
| Maximum Voltage Drop Switching Output DC [V] | 2 |
| Permanent Current Rating of Switching Output DC [mA] | 250; (per output) |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Yes (non-latching) |
| Overload Protection | Yes |
| Measuring/Setting Range |
| Maximum flow rate [l/min] | 110 |
| Temperature Monitoring |
| Measuring Range [° C] | -10 - 80 |
| Resolution [° C] | 0.2 |
| Set point SP [° C] | -9.8 - 80 |
| Reset point rP [° C] | -10 - 79.8 |
| In Steps of [° C] | 0.2 |
| Accuracy / deviations Flow monitoring |
| Accuracy (in the Measuring Range) | Water: <± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm² /s at 40 ° C): <± (5 % MW + 0,5 % MEW) |
| Repeatability | 0,2 l/min (0,05 gpm) |
| Temperature Monitoring |
| Accuracy [K] | 0,2 |
| Reaction Times Flow monitoring |
| Response Time [s] | 0.25; (dAP = 0) |
| Delay Time Programmable dS, dr [s] | 0 - 50 |
| Damping Process Value dAP [s] | 0 - 1 |
| Temperature Monitoring |
| Dynamic Response T05 / T09 [s] | T09 = 70 (Q>5 l/min); (water) |
| Software / Programming |
| Parameter Setting | Flow monitoring; Temperature Monitoring |
| Operating Conditions |
| Ambient Temperature [° C] | -10 - 60 |
| Storage Temperature [° C] | -25 - 80 |
| Protection | IP 67 |
| MTTF [Years] | 246 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Mechanical Data |
| Weight [g] | 1694 |
| Material | Housing: AlMgSi0.5 anodized; sealing: FKM; PA 6.6; cover film: PA |
| Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
| Process Connection | Threaded connection G 1 flat seal |
| Display Unit | L/min; m³/h; gpm; gph; ° C; ° F |