Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

IFM
PNP/NPN 0.5 - 75 l/min Ultrasonic Flow Meter

IFM SU7621 PNP/NPN 0.5 - 75 l/min Ultrasonic Flow Meter

Brand: IFM
Part #:
SU7621
Model #:
SUN34XXBFRKG/US
Condition:
Brand New

Choose Measuring Range (l/min)

$602.00 /Each
$607.20 You save $5.20 1%
Typically In Stock
Check availability
$602.00 /Each
$607.20 You save $5.20 1%
Manufacturer warranty

Description

$602.00 /Each
$607.20 You save $5.20 1%
Typically In Stock
Check availability

Technical details

Main features
  • Inputs Counter reset
  • Material Housing: stainless steel (1.4404 / 316L); Display: PFA; sealing Display: FKM; connector: POKAN
  • System Gold-plated contacts
  • Output Signal Switching signal; pulse signal; analog signal; IO-Link; frequency signal; diagnostic signal; totalizer switching signal
  • Communication Interface IO-Link
  • Protection Class III
  • Process Connection 3/4" NPT DN20 external thread
  • Output Function Normally open / closed; (configurable)
  • Measuring Range (l/min) 0.5 - 75
  • Electrical Design PNP/NPN
  • Protection IP 67
  • Overload Protection Yes
  • Repeatability ± 0,2 % MEW
  • Short-circuit protection Yes
  • Pulse Output Flow rate meter
  • Operating voltage [V] 18 - 32 DC; (to SELV/PELV)
  • Media Ultra-pure water; water; water-based media
  • Type of Mounting Inlet pipe length 5xDN; outlet pipe length 1xDN
  • Reverse Polarity Protection Yes
  • Measuring Principle Ultrasonic
  • Current Consumption [mA] < 75
  • Analog Current Output [mA] 4 - 20
  • Maximum Load [Ω ] 500
  • Ambient Temperature [° C] -20 - 60
  • Storage Temperature [° C] -25 - 80
  • MTTF [Years] 160
  • Weight [g] 590.5
  • Total Number of Outputs 2
  • Pressure Equipment Directive Can be used for group 2 fluids; group 1 fluids on request
  • Materials (Wetted Parts) Pipe section: stainless steel (1.4404 / 316L); Process Connection sealing: Centellen Gasket
  • Maximum Voltage Drop Switching Output DC [V] 2
  • Power-on Delay Time [s] 5
  • Response Time [s] < 0.25; (dAP = 0, T09)
  • Permanent Current Rating of Switching Output DC [mA] 100
  • Frequency at the end point FRP [Hz] 1 - 10000
  • Accuracy (in the Measuring Range) ± (2,0 % MW + 0,5 % MEW)
  • Accuracy [K] ± 2,5 (Q>5 % MEW)
  • Damping Process Value dAP [s] 0 - 5
  • Dynamic Response T05 / T09 [s] 5,7 / 86
  • Transmission Type COM2 (38,4 kBaud)
  • IO-Link Revision 1.1.3
  • SDCI Standard IEC 61131-9: 2013-07
  • Profiles Identification and Diagnosis (0x4000)
  • Required Master Port Class A
  • Process Data Analog 3
  • Process Data Binary 2
  • Minimum Process Cycle Time [ms] 9.6
  • Type of Short-Circuit Protection Yes (non-latching)
  • Pulse value 0.02 - 99990000 l; 0.005 - 26414563.515 gal
  • Pulse length [s] 0.002 - 2
  • Vacuum Resistance [mbar] -1000
  • Switching Frequency DC [Hz] 0 - 10000
  • Surface characteristics Ra/Rz of the wetted parts 49.21 μ in
  • Temperature coefficient [% of the span / 10 K] 0,2
  • Diagnostic functions Direction of flow detection; signal quality

Related items.

Customers buy together with this.

Reviews.

There are currently no reviews for this product. You can leave the first review and share your experience.

Your history.