Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Magnetic-Inductive 0.1 - 75 l/min Flow Meter
Magnetic-Inductive 0.1 - 75 l/min Flow Meter
Magnetic-Inductive 0.1 - 75 l/min Flow Meter
IFM
Magnetic-Inductive 0.1 - 75 l/min Flow Meter
Magnetic-Inductive 0.1 - 75 l/min Flow Meter
Magnetic-Inductive 0.1 - 75 l/min Flow Meter

IFM SM7420 Magnetic-Inductive 0.1 - 75 l/min Flow Meter

Brand: IFM
Part #:
SM7420
Model #:
SMK34XGXFRKG/US-100
Condition:
Brand New

Choose Measuring Range (l/min)

$910.00 /Each
Typically In Stock
Check availability
$910.00 /Each
Manufacturer warranty

Description

$910.00 /Each
Typically In Stock
Check availability

Technical details

Main features
  • Inputs Counter reset
  • Material Stainless steel (1.4408/316); stainless steel (1.4404 / 316L); PC; PBT+PC-GF30
  • System Gold-plated contacts
  • Output Signal Switching signal; analog signal; pulse signal; IO-Link; frequency signal; (configurable)
  • Communication Interface IO-Link
  • Protection Class III
  • Number of Digital Outputs 2
  • Process Connection Rc 3/4 DN20
  • Output Function Normally open / closed; (configurable)
  • Measuring Range (l/min) 0.1 - 75
  • Electrical Design PNP/NPN
  • Protection IP 65 IP 67
  • Connection Connector: 1 x M12; coding: A; Contacts: gold-plated
  • Overload Protection Yes
  • Repeatability ± 0,2 % MEW
  • Short-circuit protection Yes
  • Pulse Output Flow rate meter
  • Operating voltage [V] 18 - 30 DC; (to SELV/PELV)
  • Media Conductive liquids; water; water-based media
  • Reverse Polarity Protection Yes
  • Current Consumption [mA] < 80
  • Analog Current Output [mA] 4 - 20; (scalable)
  • Maximum Load [Ω ] 500
  • Ambient Temperature [° C] -20 - 60
  • Storage Temperature [° C] -25 - 80
  • MTTF [Years] 114
  • Weight [g] 842
  • Medium Temperature [° C] -20 - 90
  • Total Number of Outputs 2
  • Number of Analog Outputs 1
  • Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
  • Materials (Wetted Parts) Stainless steel (1.4404 / 316L); PEEK; carbon fiber PEEK; FKM
  • Maximum Voltage Drop Switching Output DC [V] 2
  • Power-on Delay Time [s] 5
  • Response Time [s] < 0.25; (dAP = 0, T09), 15; (Q>10 % MEW, T09)
  • Pressure Rating [bar] 16
  • Pressure Rating [MPa] 1.6
  • Permanent Current Rating of Switching Output DC [mA] 100
  • Frequency at the end point FRP [Hz] 1 - 10000
  • Measuring Range [° C] -20 - 90
  • Display range [° C] -42 - 112
  • Resolution [° C] 0.1
  • Set point SP [° C] -19.6 - 90
  • Reset point rP [° C] -20 - 89.6
  • In Steps of [° C] 0.1
  • Accuracy (in the Measuring Range) ± (0,8 % MW + 0,2 % MEW)
  • Accuracy [K] ± 2,5 (Q>5 % MEW)
  • Damping Process Value dAP [s] 0 - 5
  • Parameter Setting Hysteresis / window; normally open / closed; switching logic; Frequency output; current/pulse output; Start-up delay; display can be deactivated; Display Unit
  • Transmission Type COM2 (38,4 kBaud)
  • IO-Link Revision 1.1
  • SDCI Standard IEC 61131-9
  • Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
  • SIO Mode Yes
  • Required Master Port Class A
  • Process Data Analog 3
  • Process Data Binary 2
  • Minimum Process Cycle Time [ms] 6
  • Type of Short-Circuit Protection Yes (non-latching)
  • Pulse value 0.01 - 99990000 I
  • Pulse length [s] 0.003 - 2
  • Analog Start Point [° C] -20 - 68
  • Analog End Point [° C] 2 - 90
  • Start-up delay [s] 0 - 50

Related items.

Customers buy together with this.

Reviews.

There are currently no reviews for this product. You can leave the first review and share your experience.

Your history.