Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

Magnetic-Inductive 80 - 9600 gph Flow Meter
Magnetic-Inductive 80 - 9600 gph Flow Meter
Magnetic-Inductive 80 - 9600 gph Flow Meter
IFM
Magnetic-Inductive 80 - 9600 gph Flow Meter
Magnetic-Inductive 80 - 9600 gph Flow Meter
Magnetic-Inductive 80 - 9600 gph Flow Meter

IFM SM2601 Magnetic-Inductive 80 - 9600 gph Flow Meter

Brand: IFM
Part #:
SM2601
Model #:
SMN21XGXFRKG/US-100
Condition:
Brand New

Choose Measuring Range (gph)

$1,299.00 /Each
Free shipping
Typically In Stock
Check availability
$1,299.00 /Each
Manufacturer warranty

Description

$1,299.00 /Each
Free shipping
Typically In Stock
Check availability

Technical details

Main features
  • Inputs Counter reset
  • Material Stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
  • Application Totalizer function; empty pipe detection; for industrial applications
  • System Gold-plated contacts
  • Output Signal Switching signal; analog signal; pulse signal; frequency signal; IO-Link; (configurable)
  • Communication Interface IO-Link
  • Protection Class III
  • Number of Digital Outputs 2
  • Process Connection Threaded connection 2" NPT DN50
  • Output Function Normally open / closed; (configurable)
  • Measuring Range (gph) 80 - 9600
  • Electrical Design PNP/NPN
  • Protection IP 65 IP 67
  • Overload Protection Yes
  • Repeatability ± 0,2% MEW
  • Short-circuit protection Yes
  • Pulse Output Flow rate meter
  • Operating voltage [V] 18 - 32 DC; (to SELV/PELV)
  • Media Conductive liquids; water; water-based media
  • Temperature Drift ± 0,0185 ° F / K
  • Reverse Polarity Protection Yes
  • Current Consumption [mA] < 150
  • Analog Current Output [mA] 4 - 20; (scalable)
  • Maximum Load [Ω ] 500
  • MTTF [Years] 85
  • Weight [g] 2643
  • Total Number of Outputs 2
  • Number of Analog Outputs 1
  • Analog Voltage Output [V] 0 - 10; (scalable)
  • Minimum Load Resistance [Ω ] 2000
  • Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
  • Materials (Wetted Parts) Stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM
  • Pressure rating [psi] 232
  • Maximum Voltage Drop Switching Output DC [V] 2
  • Power-on Delay Time [s] 5
  • Response Time [s] 0.35; (dAP = 0)
  • Medium temperature [° F] 14 - 194
  • Pressure Rating [bar] 16
  • Ambient Temperature [° F] 14 - 140
  • Storage Temperature [° F] -13 - 176
  • Permanent Current Rating of Switching Output DC [mA] 250; (per output)
  • MAWP (for Applications According to CRN) [bar] 16
  • Frequency of the output [Hz] 0.1 - 10000
  • Measuring dynamics 1: 120
  • Accuracy (in the Measuring Range) ± (0,8 % MW + 0,5 % MEW)
  • Accuracy [K] ± 1 (77 ° F; Q>4 gpm)
  • Damping Process Value dAP [s] 0 - 5
  • Dynamic Response T05 / T09 [s] T09 = 3 (Q>4 gpm)
  • Parameter Setting Flow monitoring; quantity meter; Preset counter; Temperature Monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/frequency/pulse output; Start-up delay; display can be deactivated; Display Unit; empty pipe detection
  • Transmission Type COM2 (38,4 kBaud)
  • IO-Link Revision 1.1
  • SDCI Standard IEC 61131-9 CDV
  • Profiles Smart Sensor: Process Data Variable; Device Identification
  • SIO Mode Yes
  • Required Master Port Class A
  • Process Data Analog 3
  • Process Data Binary 2
  • Minimum Process Cycle Time [ms] 5
  • Type of Short-Circuit Protection Yes (non-latching)
  • Pulse value 0.02 - 160 E06 gal
  • In steps of 0.02 gal
  • Pulse length [s] 0,008 - 2
  • Measuring range [° F] -4 - 176
  • Display range [° F] -40 - 212
  • Resolution [° F] 0.5
  • Set point SP [° F] -2 - 176
  • In steps of [° F] 0.5
  • Delay Time Programmable dS, dr [s] 0 - 50
  • Reset point rP [° F] -3 - 175
  • Analog start point [° F] -4 - 140
  • Analog end point [° F] 32 - 176