| Product Characteristics |
| Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
| Process Connection | Threaded connection G 1/4 DN8 |
| Media | Compressed air |
| Medium Temperature [° C] | -10 - 60 |
| Electrical Data |
| Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
| Current Consumption [mA] | < 80 |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | 1 |
| Inputs / Outputs |
| Number of Inputs and Outputs | Number of Digital Outputs: 2Number of Analog Outputs: 1 |
| Inputs |
| Inputs | Teach input |
| Outputs |
| Output Signal | Switching signal; analog signal; IO-Link; (configurable) |
| Electrical Design | PNP/NPN |
| Number of Digital Outputs | 2 |
| Output Function | Normally open / closed; (configurable) |
| Maximum Voltage Drop Switching Output DC [V] | 2.5 |
| Permanent Current Rating of Switching Output DC [mA] | 150; (per output) |
| Number of Analog Outputs | 1 |
| Analog Current Output [mA] | 4 - 20; (scalable) |
| Maximum Load [Ω ] | 500 |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Yes (non-latching) |
| Overload Protection | Yes |
| Measuring/Setting Range Absolute |
| Relative (without unit of measurement) |
| Pressure monitoring |
| Measuring range [bar] | -1 - 16 |
| Display range [bar] | -1 - 20 |
| Resolution [bar] | 0.05 |
| Set point SP [bar] | -0.92 - 16 |
| Reset point rP [bar] | -1 - 15.92 |
| Analog start point [bar] | -1 - 12.8 |
| Analog end point [bar] | 2.2 - 16 |
| In steps of [bar] | 0.01 |
Flow monitoring| Accuracy / Deviations |
| Accuracy (in the Measuring Range) | ± (5% MW + 5 μ m); (pressure 1 - 3 bar) |
| Repeatability | ± (3% MW + 2 μ m); (pressure 1 - 6 bar) |
| Pressure monitoring |
| Repeatability [% of the final value] | ± 0,2 |
| Characteristics deviation [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Greatest TEMPCO of the span [% MEW / 10 K] | ± 0,3 |
| Greatest TEMPCO of the zero point [% MEW / 10 K] | ± 0,1 |
Flow monitoring| Temperature Coefficient [1/K] | ± 0,07 % MW |
| Accuracy (in the Measuring Range) | Class 141: ± (2 % MW + 1 % MEW); class 344: ± (6 % MW + 1,2 % MEW) ; air quality to ISO 8573-1: 2010; at medium temperature 23 ° C |
| Repeatability | ± (0,8 % MW + 0,4 % MEW) |
Reaction Times Pressure monitoring| Response Time [s] | 0.05 |
Flow monitoring| Response Time [s] | 0.1; (dAP = 0) |
| Damping Process Value dAP [s] | 0 - 5 |
| Software / Programming |
| Parameter Setting | Hysteresis / window; normally open / closed; current output; display can be rotated and switched off; Display Unit; Teach function |
| Interfaces |
| Communication Interface | IO-Link |
| Transmission Type | COM2 (38,4 kBaud) |
| IO-Link Revision | 1.1 |
| SDCI Standard | IEC 61131-9 |
| SIO Mode | Yes |
| Required Master Port Class | A |
| Process Data Analog | 7 |
| Process Data Binary | 2 |
| Minimum Process Cycle Time [ms] | 7.2 |
| Operating Conditions |
| Ambient Temperature [° C] | 0 - 60 |
| Storage Temperature [° C] | -20 - 85 |
| Maximum Relative Air Humidity [%] | 90 |
| Protection | |
| MTTF [Years] | 167 |
| Pressure Equipment Directive | Sound engineering practice; can be used for stable gases fluid group 2 |
| Mechanical Data |
| Weight [g] | 548.2 |
| Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM |
| Materials (Wetted Parts) | EN AW-6082 (aluminium); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate; SINT-A51; stainless steel (1.4301 / 304); CW510L (brass) |
| Process Connection | Threaded connection G 1/4 DN8 |
| Electrical Connection |
| Connection | Connector: 1 x M12; coding: A |