Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

25 - 7945 scfh Industrial Gas Counter
25 - 7945 scfh Industrial Gas Counter
25 - 7945 scfh Industrial Gas Counter
IFM
25 - 7945 scfh Industrial Gas Counter
25 - 7945 scfh Industrial Gas Counter
25 - 7945 scfh Industrial Gas Counter

IFM SD8601 25 - 7945 scfh Industrial Gas Counter

Brand: IFM
Part #:
SD8601
Model #:
SDN11DGXFRKG/US-100
Condition:
Brand New
$1,193.00 /Each
Free shipping
Typically In Stock
Check availability
$1,193.00 /Each
Manufacturer warranty

Description

$1,193.00 /Each
Free shipping
Typically In Stock
Check availability

Technical details

Main features
  • Inputs Counter reset
  • Material PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
  • Output Signal Switching signal; analog signal; pulse signal; IO-Link; (configurable)
  • Communication Interface IO-Link
  • Protection Class III
  • Number of Digital Outputs 2
  • Process Connection Threaded connection 1" NPT DN25
  • Output Function Normally open / closed; (configurable)
  • Electrical Design PNP/NPN
  • Protection IP 65 IP 67
  • Connection Connector: 1 x M12; coding: A
  • Overload Protection Yes
  • Repeatability ± (0,4 % MW + 0,1 % MEW)
  • Short-circuit protection Yes
  • Pulse Output Consumed quantity meter
  • Operating voltage [V] 18 - 30 DC; (to SELV/PELV)
  • Media Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air
  • Reverse Polarity Protection Yes
  • Current Consumption [mA] < 80
  • Analog Current Output [mA] 4 - 20; (scalable)
  • Maximum Load [Ω ] 500
  • Storage Temperature [° C] -4 - 185
  • Maximum Relative Air Humidity [%] 90
  • MTTF [Years] 183
  • Weight [g] 1608.8
  • Number of Analog Outputs 1
  • Pressure Equipment Directive Sound engineering practice; can be used for stable gases fluid group 2
  • Materials (Wetted Parts) Stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
  • Measuring range [psi] -15 - 232
  • Min. bursting pressure [psi] 928
  • Pressure rating [psi] 232
  • Maximum Voltage Drop Switching Output DC [V] 2.5
  • Power-on Delay Time [s] 1
  • Response Time [s] 0.05, 0.1; (dAP = 0)
  • Medium temperature [° F] 14 - 140
  • Repeatability [% of the final value] ± 0,2
  • Ambient Temperature [° F] 32 - 140
  • Permanent Current Rating of Switching Output DC [mA] 150; (per output)
  • MAWP (for Applications According to CRN) [bar] 10.5
  • Accuracy (in the Measuring Range) ± (6 % MW + 0,6 % MEW); (at medium temperature 73 ° F)
  • Accuracy [K] ± 0,5; (medium flow in the limit area of the flow measurement range)
  • Damping Process Value dAP [s] 0 - 5
  • Dynamic Response T05 / T09 [s] T09 = 0,5
  • Parameter Setting Hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display Unit; totalizer
  • Transmission Type COM2 (38,4 kBaud)
  • IO-Link Revision 1.1
  • SDCI Standard IEC 61131-9 CDV
  • Profiles Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
  • SIO Mode Yes
  • Required Master Port Class A
  • Process Data Analog 8
  • Process Data Binary 2
  • Minimum Process Cycle Time [ms] 7.2
  • Type of Short-Circuit Protection Yes (non-latching)
  • Pulse length [s] 0.007 - 2
  • Temperature Coefficient [1/K] ± 0,07 % MW
  • Characteristics deviation [% of the final value] < ± 0,5; (BFSL = Best Fit Straight Line)
  • Greatest TEMPCO of the span [% MEW / 10 K] ± 0,3
  • Greatest TEMPCO of the zero point [% MEW / 10 K] ± 0,1
  • Measuring range [scfh] 25 - 7945
  • Measuring range [scfm] 0.4 - 132.4
  • Measuring range [ft/s] 1.2 - 340.2
  • Display range [scfh] 0 - 9535
  • Display range [scfm] 0 - 158.9
  • Display range [ft/s] 0 - 408.2
  • Resolution [scfh] 5
  • Resolution [scfm] 0.1
  • Resolution [ft/s] 0.2
  • Set point SP [scfh] 69 - 7943
  • Set point SP [scfm] 1.1 - 132.4
  • Set point SP [ft/s] 3 - 340.1
  • Reset point rP [scfh] 30 - 7904
  • Reset point rP [scfm] 0.5 - 131.7
  • Reset point rP [ft/s] 1.3 - 338.4
  • Analog start point ASP [scfh] 0 - 6357
  • Analog start point ASP [scfm] 0 - 105.9
  • Analog start point ASP [ft/s] 0 - 272.2
  • Analog end point AEP [scfh] 1589 - 7946
  • Analog end point AEP [scfm] 26.5 - 132.4
  • Analog end point AEP [ft/s] 68 - 340.2
  • Low flow cut-off LFC [scfh] 9 - 85
  • Low flow cut-off LFC [scfm] 0.2 - 1.4
  • Low flow cut-off LFC [ft/s] 0.4 - 3.6
  • In steps of [scfh] 1
  • In steps of [scfm] 0.1
  • In steps of [ft/s] 0.1
  • Display range [psi] -15 - 290
  • Resolution [psi] 1
  • Set point SP [psi] -13 - 232
  • Reset point rP [psi] -15 - 231
  • Analog start point [psi] -15 - 186
  • Analog end point [psi] 32 - 232
  • In steps of [psi] 1

Related items.

Customers buy together with this.

Reviews.

There are currently no reviews for this product. You can leave the first review and share your experience.

Your history.