Welcome to the New PrimeBuy.comWe've upgraded our store to make finding and ordering the equipment you need faster and easier.Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page.If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed.Thank you for choosing PrimeBuy
Permanent Current Rating of Switching Output DC [mA]150; (per output)
MAWP (for Applications According to CRN) [bar]9.7
Accuracy (in the Measuring Range)± (6 % MW + 0,6 % MEW)
Accuracy [K]± 0,5; (medium flow in the limit area of the flow measurement range)
Damping Process Value dAP [s]0 - 5
Dynamic Response T05 / T09 [s]T09 = 0,5
Parameter SettingHysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display Unit; totalizer
Transmission TypeCOM2 (38,4 kBaud)
IO-Link Revision1.1
SDCI StandardIEC 61131-9 CDV
ProfilesDigital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
SIO ModeYes
Required Master Port ClassA
Process Data Analog8
Process Data Binary2
Minimum Process Cycle Time [ms]7.2
Type of Short-Circuit ProtectionYes (non-latching)
Pulse length [s]0.002 - 2
Temperature Coefficient [1/K]± 0,07 % MW
Characteristics deviation [% of the final value]< ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span [% MEW / 10 K]± 0,3
Greatest TEMPCO of the zero point [% MEW / 10 K]± 0,1
Measuring range [scfh]8 - 2648
Measuring range [scfm]0.15 - 44.15
Measuring range [ft/s]1 - 327.4
Display range [scfh]0 - 3178
Display range [scfm]0 - 52.95
Display range [ft/s]0 - 393
Resolution [scfh]2
Resolution [scfm]0.05
Resolution [ft/s]0.2
Set point SP [scfh]23 - 2648
Set point SP [scfm]0.38 - 44.13
Set point SP [ft/s]2.8 - 327.3
Reset point rP [scfh]10 - 2635
Reset point rP [scfm]0.16 - 43.91
Reset point rP [ft/s]1.2 - 325.7
Analog start point ASP [scfh]0 - 2119
Analog start point ASP [scfm]0 - 35.31
Analog start point ASP [ft/s]0 - 261.9
Analog end point AEP [scfh]530 - 2649
Analog end point AEP [scfm]8.83 - 44.14
Analog end point AEP [ft/s]65.5 - 327.4
Low flow cut-off LFC [scfh]3 - 28
Low flow cut-off LFC [scfm]0.05 - 0.47
Low flow cut-off LFC [ft/s]0.4 - 3.5
In steps of [scfh]1
In steps of [scfm]0.01
In steps of [ft/s]0.1
Display range [psi]-15 - 290
Resolution [psi]1
Set point SP [psi]-13 - 232
Reset point rP [psi]-15 - 231
Analog start point [psi]-15 - 186
Analog end point [psi]32 - 232
In steps of [psi]1