Welcome to the New PrimeBuy.com We've upgraded our store to make finding and ordering the equipment you need faster and easier. Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page. If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed. Thank you for choosing PrimeBuy

PNP/NPN 232PSI Compressed Air Meter
PNP/NPN 232PSI Compressed Air Meter
PNP/NPN 232PSI Compressed Air Meter
IFM
PNP/NPN 232PSI Compressed Air Meter
PNP/NPN 232PSI Compressed Air Meter
PNP/NPN 232PSI Compressed Air Meter

IFM SD2500 PNP/NPN 232PSI Compressed Air Meter

Brand: IFM
Part #:
SD2500
Model #:
SDR21DGXFRKG/US-100
Condition:
Brand New

Choose Electrical Design

$1,473.00 /Each
Free shipping
Typically In Stock
Check availability
$1,473.00 /Each
Manufacturer warranty

Description

$1,473.00 /Each
Free shipping
Typically In Stock
Check availability

Technical details

Main features
  • Inputs Counter reset
  • Material PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
  • Output Signal Switching signal; analog signal; pulse signal; IO-Link; (configurable)
  • Communication Interface IO-Link
  • Protection Class III
  • Number of Digital Outputs 2
  • Process Connection Threaded connection R 2 DN50
  • Output Function Normally open / closed; (configurable)
  • Electrical Design PNP/NPN
  • Protection IP 65 IP 67
  • Connection Connector: 1 x M12; coding: A
  • Overload Protection Yes
  • Repeatability ± (0,4 % MW + 0,1 % MEW)
  • Short-circuit protection Yes
  • Pulse Output Consumed quantity meter
  • Operating voltage [V] 18 - 30 DC; (to SELV/PELV)
  • Media Compressed air
  • Reverse Polarity Protection Yes
  • Current Consumption [mA] < 80
  • Analog Current Output [mA] 4 - 20; (scalable)
  • Maximum Load [Ω ] 500
  • Ambient Temperature [° C] 0 - 60
  • Storage Temperature [° C] -20 - 85
  • Maximum Relative Air Humidity [%] 90
  • MTTF [Years] 183
  • Weight [g] 2650.5
  • Medium Temperature [° C] -10 - 60
  • Number of Analog Outputs 1
  • Pressure Equipment Directive Sound engineering practice; can be used for stable gases fluid group 2
  • Materials (Wetted Parts) Stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
  • Maximum Voltage Drop Switching Output DC [V] 2.5
  • Power-on Delay Time [s] 1
  • Response Time [s] 0.05, 0.1; (dAP = 0)
  • Pressure Rating [bar] 16
  • Pressure Rating [MPa] 1.6
  • Repeatability [% of the final value] ± 0,2
  • Permanent Current Rating of Switching Output DC [mA] 150; (per output)
  • Min. bursting pressure [bar] 64
  • MAWP (for Applications According to CRN) [bar] 9.5
  • Accuracy (in the Measuring Range) Class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1: 2010; at medium temperature 23 ° C
  • Accuracy [K] ± 0,5; (medium flow in the limit area of the flow measurement range)
  • Damping Process Value dAP [s] 0 - 5
  • Dynamic Response T05 / T09 [s] T09 = 0,5
  • Parameter Setting Hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display Unit; totalizer
  • Transmission Type COM2 (38,4 kBaud)
  • IO-Link Revision 1.1
  • SDCI Standard IEC 61131-9 CDV
  • Profiles Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
  • SIO Mode Yes
  • Required Master Port Class A
  • Process Data Analog 8
  • Process Data Binary 2
  • Minimum Process Cycle Time [ms] 7.2
  • Type of Short-Circuit Protection Yes (non-latching)
  • Pulse length [s] 0.002 - 2
  • Min. bursting pressure [MPa] 6.4
  • Measuring range [bar] -1 - 16
  • Display range [bar] -1 - 20
  • Resolution [bar] 0.05
  • Set point SP [bar] -0.92 - 16
  • Reset point rP [bar] -1 - 15.92
  • Analog start point [bar] -1 - 12.8
  • Analog end point [bar] 2.2 - 16
  • In steps of [bar] 0.01
  • Temperature Coefficient [1/K] ± 0,07 % MW
  • Characteristics deviation [% of the final value] < ± 0,5; (BFSL = Best Fit Straight Line)
  • Greatest TEMPCO of the span [% MEW / 10 K] ± 0,3
  • Greatest TEMPCO of the zero point [% MEW / 10 K] ± 0,1