| Product Characteristics |
| Number of Inputs and Outputs | Number of Digital Outputs: 2 |
| Process Connection | Threaded connection G 1/4 external thread Internal thread: M5 |
| Media | Liquids and gases |
| Conditionally Suitable for | Use in gases at pressures>25 bar only on request |
| Medium Temperature [° C] | -25 - 90 |
| Type of Pressure | Relative pressure |
| Electrical Data |
| Operating Voltage [V] | 9.6 - 36 DC; (communication mode: 18 - 32) |
| Current Consumption [mA] | < 45 |
| Minimum Insulation Resistance [MΩ ] | 100; (500 V DC) |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power-on Delay Time [s] | 0.3 |
| Inputs / Outputs |
| Number of Inputs and Outputs | Number of Digital Outputs: 2 |
| Outputs |
| Total Number of Outputs | 2 |
| Output Signal | Switching signal |
| Electrical Design | NPN |
| Number of Digital Outputs | 2 |
| Output Function | Normally open / closed; (configurable) |
| Maximum Voltage Drop Switching Output DC [V] | 2 |
| Permanent Current Rating of Switching Output DC [mA] | 250 |
| Switching Frequency DC [Hz] | 170 |
| Short-Circuit Protection | Yes |
| Type of Short-Circuit Protection | Yes (non-latching) |
| Overload Protection | Yes |
| Accuracy / Deviations |
| Switch Point Accuracy [% of the Span] | < ± 0,5 |
| Repeatability [% of the Span] | < ± 0,1; (with temperature fluctuations<10 K) |
| Characteristics Deviation [% of the Span] | < ± 0,25 (BFSL) /<± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis Deviation [% of the Span] | < ± 0,1 |
| Long-Term Stability [% of the Span] | < ± 0,1; (per year) |
| Temperature coefficient Zero Point [% of the Span / 10 K] | < ± 0,2; (0 - 80 ° C) |
| Temperature Coefficient Span [% of the Span / 10 K] | < ± 0,2; (0 - 80 ° C) |
| Reaction Times |
| Response Time [ms] | < 3 |
| Damping Process Xalue dAP in Steps [s] | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
| Operating Conditions |
| Ambient Temperature [° C] | -25 - 85 |
| Storage Temperature [° C] | -40 - 100 |
| Protection | IP 68; (7 days / 1 m water depth / 0.1 bar) |
| MTTF [Years] | 309 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Mechanical Data |
| Weight [g] | 226 |
| Material | Stainless steel (1.4301 / 304); FKM; EPDM/X; PA |
| Materials (Wetted Parts) | Stainless steel (1.4305 / 303); ceramics; FKM |
| Minimum Pressure Cycles | 100 million |
| Process Connection | Threaded connection G 1/4 external thread Internal thread: M5 |
| Restrictor Element Integrated | No (can be retrofitted) |
| Teach function | Yes |
| Electrical Connection |
| Connection | Connector: 1 x M12; coding: A |