Product Characteristics |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Process Connection | Threaded connection G 1/4 Internal thread |
System | gold-plated contacts |
Measuring Element | Ceramic-capacitive pressure measuring cell |
Media | liquids and gases |
Conditionally Suitable for | Use in gases at pressures>25 bar only on request |
Medium Temperature [°C] | -25 - 80 |
Vacuum Resistance [mbar] | -1000 |
Type of Pressure | Relative pressure |
Electrical Data |
Operating Voltage [V] | 18 - 30 DC; (to SELV/PELV) |
Current Consumption [mA] | <35 |
Minimum Insulation Resistance [MΩ] | 100; (500 V DC) |
Protection Class | III |
Reverse Polarity Protection | Yes |
Power-on Delay Time [s] | <0.3 |
Integrated Watchdog | Yes |
Inputs / Outputs |
Number of Inputs and Outputs | Number of Digital Outputs: 2 |
Outputs |
Total Number of Outputs | 2 |
Output Signal | Switching signal; IO-Link; (configurable) |
Electrical Design | PNP/NPN |
Number of Digital Outputs | 2 |
Output Function | Normally open / closed; (configurable) |
Maximum Voltage Drop Switching Output DC [V] | 2.5 |
Permanent Current Rating of Switching Output DC [mA] | 150; (200 ( - 60 °C) 250 ( - 40 °C)) |
Switching Frequency DC [Hz] | <170 |
Short-Circuit Protection | Yes |
Type of Short-Circuit Protection | Yes (non-latching) |
Overload Protection | Yes |
Measuring/Setting Range |
Accuracy / Deviations |
Switch Point Accuracy [% of the Span] | ± 0,5 |
Repeatability [% of the Span] | ± 0,1; (with temperature fluctuations<10 K) |
Characteristics Deviation [% of the Span] | ± 0,25 (BFSL) /<± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis Deviation [% of the Span] | ± 0,25 |
Long-Term Stability [% of the Span] | ± 0,05; (per 6 months) |
Temperature coefficient Zero Point [% of the Span / 10 K] | ± 0,2; (0 - 80 °C) |
Temperature Coefficient Span [% of the Span / 10 K] | ± 0,2; (0 - 80 °C) |
Reaction Times |
Response Time [ms] | <3 |
Delay Time Programmable dS, dr [s] | 0 - 50 |
Damping Process Value dAP [s] | 0 - 4 |
Software / Programming |
Parameter Setting | Hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display Unit |
Interfaces |
Communication Interface | IO-Link |
Transmission Type | COM2 (38,4 kBaud) |
IO-Link Revision | 1.1 |
SDCI Standard | IEC 61131-9 |
Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
SIO Mode | Yes |
Required Master Port Class | A; (when pin 2 not connected: B) |
Minimum Process Cycle Time [ms] | 3 |
IO-Link Resolution Pressure [bar] | 0.2 |
IO-Link Functions (Acyclical) | Application specific tag |
Operating Conditions |
Ambient Temperature [°C] | -25 - 80 |
Storage Temperature [°C] | -40 - 100 |
Protection | |
MTTF [Years] | 249 |
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical Data |
Weight [g] | 280 |
Material | Stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (Wetted Parts) | Stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM |
Minimum Pressure Cycles | 100 million |
Tightening Torque [Nm] | 25 - 35; (recommended tightening torque; Depends on lubrication, seal and pressure rating) |
Process Connection | Threaded connection G 1/4 Internal thread |
Restrictor Element Integrated | No (can be retrofitted) |
Electrical Connection |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |