Welcome to the New PrimeBuy.comWe've upgraded our store to make finding and ordering the equipment you need faster and easier.Returning customers: your account and order history have moved to the new site. To sign in for the first time, please set a new password using “” on the sign-in page.If anything gets in the way of your order, or you notice something that isn't working as it should, let us know through live chat or email. A member of our team will help you and make sure it gets fixed.Thank you for choosing PrimeBuy
Output SignalSwitching signal; analog signal; IO-Link; (configurable)
Communication InterfaceIO-Link
Protection ClassIII
Number of Digital Outputs2
Process ConnectionThreaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a Process Connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.
Output FunctionNormally open / closed; (configurable)
Electrical DesignPNP/NPN
ProtectionIP 67 IP 68 IP 69K
ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated
Overload ProtectionYes
Short-circuit protectionYes
Operating voltage [V]18 - 32 DC, 20 - 32 DC
Mediaviscous media and liquids with suspended particles; liquids and gases
Reverse Polarity ProtectionYes
Current Consumption [mA]<45, 3.6 - 21
Analog Current Output [mA]4 - 20, invertible; (scalable)
MTTF [Years]148.85
Weight [g]379
Type of PressureRelative pressure; vacuum
Total Number of Outputs2
Number of Analog Outputs1
Repeatability [% of the Span]± 0,1; (with temperature fluctuations<10 K; Turn down 1: 1)
Characteristics Deviation [% of the Span]± 0,2; (Turn down 1: 1, linearity, incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Long-Term Stability [% of the Span]± 0,1; (Turn down 1: 1; per year)
Temperature coefficient Zero Point [% of the Span / 10 K]± 0,05; (0 - 70 °C)
Temperature Coefficient Span [% of the Span / 10 K]± 0,15; (0 - 70 °C)
Permanent Current Rating of Switching Output DC [mA]250
MAWP (for Applications According to CRN) [bar]30
Damping Process Value dAP [s]0 - 30
Damping for the Analog Output dAA [s]0.01 - 99.99
Transmission TypeCOM2 (38,4 kBaud)
IO-Link Revision1.0
ProfilesNo profile
SIO ModeYes
Required Master Port ClassA
Process Data Analog1
Process Data Binary2
Minimum Process Cycle Time [ms]2.3
Type of Short-Circuit ProtectionYes (non-latching)
Ambient Temperature [°C]-25 - 80
Storage Temperature [°C]-40 - 100
Medium Temperature [°C]-25 - 125; (145 Maximum 1h)
Minimum Insulation Resistance [MΩ]100; (500 V DC)
Maximum Load [Ω]300, (Ub - 10 V) / 20 mA
Vacuum Resistance [mbar]-1000
Linearity Deviation [% of the span]± 0,15; (Turn down 1: 1)
Hysteresis Deviation [% of the Span]± 0,15; (Turn down 1: 1)
Integrated WatchdogYes
Switching Frequency DC [Hz]125
Switch Point Accuracy [% of the Span]± 0,2; (Turn down 1: 1)
Display UnitBar; psi; kPa; % of the span
Minimum Response Time of Switching Output (dAP) [ms]3