Gossen Metrawatt, M205A, MetraHit 2+ TRMS Digital Multimeter with Analog Bar Graph and Temperature Measuring Instrument
M205A Includes Only:
- 1 TRMS-Digital-Multimeter
- 1 protective rubber holster
- 2 2 x 1.5 V AA size batteries
- 1 set of measurement cables KS17-ONE
- 1 DAkkS calibration certificate
- 1 Short-form operating instructions
- Continuity and diode testing
- Min-Max measured value storage and Data Hold
DAkkS calibration certificate included as standard feature
Features:
- Automatic Blocking Sockets (ABS): Automatic blocking sockets prevent incorrect connection of measurement cables and inadvertent selection of the wrong measured quantity. This significantly reduces the danger to the user, the instrument, and the system under test, and eliMinates it entirely in many cases.
- Automatic / Manual Measuring Range Selection: Measured quantities are selected with the rotary switch. The measuring range is automatically matched to measured values. The measuring range can be selected manually as well with the help of the auto/man key.
- Display of Negative Values at the Analog Scale: Negative values are also displayed at the analog scale for zero frequency quantities, allowing for observation of measured quantity fluctuation around the zero-point.
- Storage of Measured Values: By pressing the Hold/Min/Max key, the currently displayed measurement value can be „frozen" in the display. The Minimum and Maximum values which were present at the input of the measuring instrument after activation of the Min/Max mode can be selectively "retained" with the Min/ Max function. The most important application is the deterMination of the Minimum or Maximum value during long-term observation of measurement quantities. Min/Max has no effect on the analog display; it continues to display the current measurement value.
- Continuity Test: Allows for the detection of short circuits and interrupted conductors. In addition to displaying test results, an acoustic signal can also be generated if desired.
- Power Saving Circuit: The device is switched off automatically if the measured value remains unchanged for a period of approximately 10 Minutes, and if none of the controls are activated during this time. The automatic shutdown can be deactivated.
- Protective Cover for Harsh Conditions: The instrument is protected against damage in the event of impacts or dropping by means of a soft rubber cover with a tilt stand. The rubber material also assures that the instrument does not wander if it is set up on a vibrating surface.
- RMS Measurement with Distorted Waveshapes: The measuring method applied allows for RMS measurement for alternating signals (AC) in voltage and current measurement, independent of the waveshape up to 1 kHz (for non-sinusoidal signals as well).