| Generator |
| Rated maximum continuous power capacity (LP) | 14,000 Watts |
| Rated maximum continuous power capacity (NG) | 14,000 Watts |
| Rated voltage | 240 |
| Rated maximum continuous load current – 240 volts (LP / NG) | 58.3 / 58.3 |
| Total Harmonic Distortion | Less than 5% |
| Main line circuit breaker | 60 Amp |
| Phase | 1 |
| Number of rotor poles | 2 |
| Rated AC frequency | 60Hz |
| Power Factor | 1 |
| Battery requirement (not included) | 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum |
| Unit weight (lb / kg) | 385/175 |
| Dimensions (L x W x H) in / cm | 48 x 25 x 29 / 121.9 x 63.5 x 73.7 |
| Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load | 65 |
| Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode | 55 |
| Exercise duration | 5 min |
| Engine |
| Engine type | GENERAC G-Force 800 Series |
| Number of cylinders | 2 |
| Displacement | 816 cc |
| Cylinder block | Aluminum w/ Cast Iron Sleeve |
| Valve arrangement | Overhead valve |
| Lifter type | Hydraulic |
| Ignition system | Solid-state w/ Magneto |
| Governor system | Electronic |
| Compression ratio | 9.5:1 |
| Starter | 12 VDC |
| Oil capacity including filter | Approx. 2.2 qt/2.1 L |
| Operating rpm | 3,600 |
| Controls |
| Two-line plain text multilingual LCD | Simple user interface for ease of operation |
| Mode buttons |
| AUTO | Automatic start on utility failure. Weekly, Bi-Weekly, or Monthly selectable exerciser. |
| OFF | Stops unit. Power is removed. Control and charger still operate |
| MANUAL | Start with starter control, unit stays on. If utility fails, transfer to load takes place. |
| Ready to Run/Maintenance messages | Standard |
| Engine run hours indication | Standard |
| Programmable start delay between 2–1500 seconds | Standard (programmable by dealer only) |
| Utility Voltage Loss/Return to Utility adjustable (brownout setting) | From 140-171 V / 190-216 V |
| Future Set Capable Exerciser/Exercise Set Error warning | Standard |
| Run/Alarm/Maintenance logs | 50 events each |
| Engine start sequence | Cyclic cranking: 16 sec on, 7 sec rest (90 sec maximum duration). |
| Starter lock-out | Starter cannot re-engage until five seconds after engine has stopped |
| Smart Battery Charger | Standard |
| Charger Fault/Missing AC warning | Standard |
| Low Battery/Battery Problem Protection and Battery Condition indication | Standard |
| Automatic Voltage Regulation with Over and Under Voltage Protection | Standard |
| Under-Frequency/Overload/Stepper Overcurrent Protection | Standard |
| Safety Fused/Fuse Problem Protection | Standard |
| Automatic Low Oil Pressure/High Oil Temperature Shutdown | Standard |
| Overcrank/Overspeed ( at 72 Hz)/rpm Sense Loss Shutdown | Standard |
| High Engine Temperature Shutdown | Standard |
| Internal Fault/Incorrect Wiring protection | Standard |
| Common external fault capability | Standard |
| Field upgradable firmware | Standard |
| Switch Options |
| No. of poles | 2 |
| Current rating (amps) | 200 |
| Voltage rating (VAC) | 120 / 240, 1ø |
| Utility voltage monitor (fixed) |
| Pick-up | 80% |
| Dropout | 65% |
| Return to utility | 15 sec |
| Exercises bi-weekly for 5 minutes | Standard |
| ETL or UL Listed | Standard |
| Enclosure type | NEMA/UL 3R |
| Circuit breaker protected | 22,000 |
| Lug range | 250 MCM - #6 |