Features:
- This switch should be positioned to match the line voltage for proper operation.
- When the line voltage goes below (brown out) or above the preselected operating range, the internal relay drops out removing the plugged-in appliance from these adverse fault conditions.
- When the voltage returns to the normal operating range, a five (5) minute delay begins.
- Upon completion, the internal relay picks up allowing the plugged-in appliance to start.
- LED indicators give an immediate visual reference as to the status of the control. The GREEN LED indicates conditions are normal.
- When a fault condition occurs the GREEN LED will extinguish and the RED LED will glow.
- When a fault condition has been corrected, the RED LED will begin to flash. The RED LED will continue to flash until the five (5) minute delay period elapses.
- At the end of the delay period the RED LED will extinguish and the GREEN LED will glow.
- When both LED's are extinguished, a total loss of power is indicated
For more information, please see
Data Sheet