| Rated input current (Maximum Load) | 10.8A |
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS Input Connection Type | 5-15P |
| Input Circuit Breakers | 20A |
| UPS Input Cord Length (ft.) | 6 |
| Recommended Electrical Service | 15A 120V |
| Input Phase | Single-Phase |
| Output Volt Amp Capacity (VA) | 1300 |
| Output kVA Capacity (kVA) | 1.3 |
| Output Watt Capacity (Watts) | 720 |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Frequency Compatibility | 60 Hz |
| Output Voltage Regulation (Line Mode) | 120V (+9% / -12%) |
| Output Voltage Regulation (Battery Mode) | 120V (±10%) |
| UPS Output Receptacles (Surge Suppression Only) | 4 UPS outlets, 4 surge-only outlets |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Output Receptacles | (8) 5-15R |
| Individually Controllable Load Banks | No |
| Half Load Runtime (min.) | 10 minutes (360 watts) |
| DC System Voltage (VDC) | 24 |
| Battery Recharge Rate (Included Batteries) | Less than 6.3 hours from 10% to 90% |
| Expandable Runtime | No |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150 |
| Overvoltage Correction | Input voltages between 129 and 150 are reduced by 15% |
| Undervoltage Correction | Input voltages between 92 and 108 are boosted by 18% |
| Front Panel LCD Display | LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes |
| Switches | Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm | Audible alarm indicates power-failure and low-battery conditions |
| UPS AC Suppression Joule Rating | 650 |
| UPS AC Suppression Response Time | Instantaneous |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set) |
| EMI / RFI AC Noise Suppression | Yes |
| Cooling Method | Fan |
| Primary Form Factor | Tower |
| Primary UPS Depth (mm) | 396 |
| Primary UPS Height (mm) | 203 |
| Primary UPS Width (mm) | 146 |
| Shipping Dimensions (hwd / in.) | 11.30 x 9.10 x 19.40 |
| Shipping Weight (lbs.) | 24.70 |
| UPS Power Module Dimensions (hwd, in.) | 8 x 5.75 x 15.6 |
| UPS Power Module Weight (kg) | 9.39 |
| UPS Power Module Weight (lbs.) | 20.7 |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 5 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) | 100 |
| Battery Mode BTU / Hr. (Full Load) | 776 |
| AC Mode Efficiency Rating (100% Load) | 95% |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power condition |
| Communications Cable | USB cabling included |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Communications Interface | USB (HID enabled) |
| Transfer Time | 2 milliseconds (AC to battery mode), 6 milliseconds (battery to AC mode) |
| Low Voltage Transfer to Battery Power (Setpoint) | 92 |
| High Voltage Transfer to Battery Power (Setpoint) | 150 |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Hot swappable batteries |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |