Power Source | Usable power supply unit: VX-200PS 24 V DC (operational range: 20 V - 40 V DC) Two power inputs construction enables dual- redundant power supply. |
Current Consumption | 2.01 A or less (maximum value in the power operating range) 1.50 A or less (when operated on 24 V DC) Note: But except current consumption of the external equipment of which power is supplied from the unit. |
Indication | 18 alphanumeric characters, Level indication (8 inputs, monitor), Status indicators, POWER indicator, STANDBY indicator, CPU OFF indicator |
Operation | Function button, Input level control, Monitor speaker volume control, ON/OFF switch, Operation button |
Audio Input | 8 inputs, module construction (max. 4 modules, modules optional) monitoring possible using built-in speaker. |
Audio Input Characteristic | Sampling frequency: 48 kHz |
No. of Connectable Remote Microphone | Max. 8 |
Power Feed to Remote Microphone | Possible for up to a total of 8 A. |
Network I/F | 2 100BASE-TX circuits, RJ45 connector, decentralized installation possible |
Connection Cable/Device | Shielded Category 5 twisted pair cable (CAT5-STP) To be connected via the switching hub specified by TOA Note: This network must be made completely independent from other LAN. |
Maximum Cable Distance | 100 m (32.81 ft) (between this unit and a switching hub) |
Input/Output Connector | Input: 1 input, RJ45 connector Output: 1 output, RJ45 connector |
Connection Cable | Shielded Category 5 twisted pair cable (CAT5-STP) (1 pair of audio wire + 1 pair of control wire (CPU OFF) + 1 pair of control wire (system reset/standby) + 1 pair of connection check wire) |
Maximum Cable Distance | Total length of analog link: 800 m (874.89 yd) |
Control Input | 16 inputs, no-voltage make contact input, open voltage: 40 V DC or less, short-circuit current: 2 mA, photo coupler input, removable terminal block (16 pins) |
Control Output | 16 outputs, Form A contact: normally open (changeable to Form B contact: normally closed), no-voltage make contact output, relay contact output (withstand voltage: 40 V DC, control current: 2 - 300 mA), removable terminal block (16 pins) |
Operating Temperature | 0 °C to +40 °C (32 °F to 104 °F) |
Operating Humidity | 35 % to 80 %RH (no condensation) |
Finish | Panel: Aluminum, black, alumite Case: Surface-treated steel plate |
Dimensions | 482 (W) x 88.4 (H) x 349 (D) mm (18.98" x 3.48" x 13.74") |
Weight | 7.2 kg (15.87 lb) |